Spec Sheet

Product Comparison Guide
PRODUCT DISTINCTIONS
SECURITRON AQL
SERIES
COMPETITOR 1
SECURITRON AQD/AQS
SERIES (110 VAC)
COMPETITOR 2
Dual voltage capability B100 (5–18 VDC) 5 or 12 VDC only
Integrated competitor mounting holes on PCB Yes AQD6 only
Standard lockset / tamperswitch Lockset & tamper Lockset only Lockset only Lockset only
On board current sensors (reported to Network Monitor)
Battery current
Requires Securitron
Netlink sensor
Output current
POWER SUPPLY *Two separate boards *Two separate boards
AC input — (* separate models for 120 V or 230 VAC) 120 or 230 VAC *120 VAC | 230 VAC 120 or 230 VAC *120 VAC | 230 VAC
Warranty (NF/NQA — no-fault, no questions asked lifetime) NF/NQA Lifetime Limited Lifetime NF/NQA Lifetime Limited Lifetime
Built-in fire alarm disconnect
Overtemperature protection
Power supply derating at 120˚ F [49˚ C] 100% 100% 100% 100%
Power supply run-time monitoring
Computer or network interface
Comprehensive fault detection
POWER OUTPUTS
LockSafe™ — separate voltages for DC output
Dual Buss distribution architecture
Limited accessory boards
Auxiliary output 1.5 A 1 A
POWER SUPPLY REPORTING & VISUAL INDICATORS
FAI, reverse battery detect
Power supply internal fault counter with reset
Battery install date & time counter
Requires accessory
Customizable AC and system fault delay periods
Requires accessory
Visual Indicators
FAI indication
OutSmart™ Bi-Color 12/24 V LED Indication
Limited accessory boards
System fault indicator
BATTERY CHARGING
Smart charger — programmable current for optimum charging
Charger type CC-CV Fixed current charger CC-CV PTC limiting charger
Dedicated battery charge current
(except AQD1)
Maximum battery charge current 1 A /1.6 A 1.54 A 0.1 A–1.5 A based on model 0.7 A
Maximum battery charge capability (48-hours charging) 40 AH/65 AH 65 AH Varies up to 65 AH 18 AH/18 AH
Low battery disconnect prevents deep discharge Built-in Built-in Built-in
BATTERY MANAGEMENT & MONITORING
Battery parameters monitored by the power supply
Charging current and voltage
Battery presence
Battery parameters monitored through network connection
Required battery backup time
Actual battery backup time (with alert when backup time failed)
System running on battery
Battery replacement date
Battery life time — total hours
Low or dead battery
NETWORK MANAGEMENT
Power supply network capable
Power supply data connection method
#
1 SPI
Email / SNMP fault notification
Network control
One-click or scheduled battery load testing
1000 Event data recorder, user can export record to CSV file
100 events
Network reporting
On AC loss or system fault
When FAI activated
Cybersecurity, integrations
Cybersecurity enhancement with 3rd party pen test and report
AGENCY LISTINGS
USA Access, Fire, Security, CFSM Access, Fire, Security, CFSM Access, Fire, Security, CFSM Access, Fire, Security, CFSM
Canada Access, Security Access, Security Access, Security Access, Security