Installation Instructions

Application Examples
Dual Voltage 24 V | 12 V
Using
One (1) Securitron AQL Power Supply
One (1) Securitron B100 Secondary Voltage Module
Dual Voltage 24 V | 12 V
Using
One (1) Securitron AQL Power Supply
One (1) Securitron B100 Secondary Voltage Module
One (1) Securitron D8/D8P Power Distribution Module
Multi Voltage
24 V | 12 V | 5 V
Using
One (1) Securitron AQL Power Supply
Two (2) Securitron B100 Secondary Voltage Modules
– OUT +
DC IN
DC OUT
BR
DC IN
BR
DC OUT
12 V OUT
Securitron B100 set to 12 VDC
FlexIOFlexIO
FlexIO connectionFlexIO connection
Securitron AQL
24 V
FlexIOFlexIO
Each output selectable for
24 V (B1) or 12 V (B2)
B1
B2
BR
B1
B2
BR
FlexIOFlexIO FlexIOFlexIO
12 V OUT
FlexIO connectionFlexIO connection
– OUT +
DC IN
BR
DC IN
BR
DC OUT
DC OUT
Securitron B100 – set to 12 VDC
FlexIOFlexIO
FlexIO connectionFlexIO connection
Securitron
D8
Securitron AQL
24 V
– OUT +
DC OUT
DC OUT
FlexIOFlexIO
– OUT +
DC IN
BR
DC IN
BR
DC IN
BR
DC IN
BR
DC OUT DC OUT
Securitron B100 – set to 12 VDC Securitron B100 set to 5 VDC
FlexIOFlexIO
FlexIOFlexIO
FlexIO connectionFlexIO connection
5 V OUT
12 V OUT
Securitron AQL
24 V
FlexIO connectionFlexIO connection
FlexIO connectionFlexIO connection
5 V OUT
Each output selectable for
24 V (B1) or 5 V (B2)
B1
B2
BR
B1
B2
BR
– OUT +
DC OUT
BR
DC OUT
BR
DC IN
DC IN
FlexIOFlexIO
Each output selectable for
24 V (B1) or 12 V (B2)
B1
B2
BR
B1
B2
BR
12 V OUT
FlexIO connectionFlexIO connection
– OUT +
DC IN
BR
DC IN
BR
DC OUT
DC OUT
Securitron B100 – set to 12 VDC
Securitron B100 – set to 5 VDC
FlexIOFlexIO
FlexIOFlexIO
FlexIOFlexIOFlexIOFlexIO
FlexIOFlexIO
FlexIO connectionFlexIO connection
Securitron
D8
Securitron
D8
Securitron AQL
24 V
FlexIOFlexIO
Multi Voltage
24 V | 12 V | 5 V
Using
One (1) Securitron AQL Power Supply
Two (2) Securitron B100
Secondary Voltage Modules
Two (2) Securitron D8/D8P Power
Distribution Modules
16