Securitron Magnalock Corp. www.securitron.com Tel 800.624.5625 techsupport@securitron.com ® M670/M680 MAGNALOCK SERIES Installation Instructions Table of Contents Specifications 2 Configuring Options 3 Installation Guide 6 Wiring Diagram 14 Error Codes 16 Scan this QR Code for a guided installation video. Alternatively Quick Clips are available in each section.
Recommended Tools Masking Tape #0, #1 and #2 Phillips Screwdrivers Hammer Measuring Device 1/2” Open End or Crescent Wrench Pencil/Pen Center Punch Wire Strippers/Cutter Multimeter Fish Tape or Lead Wire 3/16” Hex (Allen) Wrench Drill bits: 3/16”, 7/32” (wood frames only), 3/8”, 1/2” M670 / M680BD Specifications Mechanical Electrical Physical Size: Height: 2-1/2” [66mm] Depth: 2-1/2” [66mm] Length: 11-1/2” [292mm] Shipped Weight: Weight: 13 lbs Holding Force (Maximum) 1,100 Lbs.
Magnalock Preparation 1. Using a Phillips screwdriver, remove the two (2) screws securing the cover as shown. Remove the cover to provide access to the circuit board on the back of the magnet. The screws should be saved to re-attach the cover later. 2. Component Locations Quick Clip 1: SW2 Configuration Page 3 PN# 500-10550 Rev.
Component Label JP1 Component Name Jumper 1: Tamper Switch Mode Select A 3-pin jumper that controls the output setting for Tamper Switch SW1 at Terminal Block J1.
J1 Terminal Block 1 Tamper Switch A 2-wire terminal block providing a SPDT contact that changes state as determined by JP1 when the cover is sensed to be removed by SW1. J5 Terminal Block 5 Input Power A 2-wire terminal block providing connection to the power supply. Position 1 is (+). Position 2 is (-). J6 Terminal Block 6 BondSTAT A 3-wire terminal block providing a SPDT 1-Form C contact that changes state when the BondSTAT bond is interrupted.
Magnalock Installation 1. CRemove three (3) screws securing lock to mounting Hbracket and slide the bracket from the top of the 1lock chassis. 2. Pinch and insert spacers flush into the dovetail slots of the lock-mounting bracket. 3. Mark Mounting Holes: Use masking tape to protect the door and frame surfaces during marking and drilling. Place the lock bracket on the secure side of the door against the frame stop toward the side of the door that does not have hinges.
5. Metal Door Frame - Drill Mounting Holes: Note: If installing on a wood door frame, go to Step 7. Drill two (2) 3/8” diameter holes at bracket-mounting hole marks. 3/8” diameter (METAL) 3/8” diameter (METAL) Note: Do not oversize the hole. Use a step bit or pilot hole first to ensure a snug fit for the blind nuts. 6. Blind Nut Installation: Use the tool provided to install blind nuts into each 3/8” diameter hole. Hold the collapsing nut with a 1/2” box end wrench.
7. Wood Door Frame – Drill Mounting Holes: Drill two (2) 3/16” diameter holes at bracket-mounting hole marks. Drill 1 ¼” deep. 3/16” diameter (WOOD) 3/16” diameter (WOOD) 8. Drill Wire Access Holes Drill wire access holes as needed on one (1) or both sides of the bracket location. ½” diameter is recommended for wire access. 9. Install Bracket: Use a Phillips screwdriver to temporarily install the bracket with spacers against the closed door.
Strike Installation 1. Close the door and place the template between the bracket spacers. Quick Clip 4: Mark the strike plate hole locations. Bracket spacers can now be removed from the bracket. Bracket Spacers Strike Installation 2. From INSIDE the door: Drill one (1) 3/8” diameter hole for the sex bolt through the door at the strike mounting center mark. Drill two (2) 3/8” diameter x 1” deep holes at each side mark for the strike alignment roll pins. Do not drill through the door.
4. Install Roll Pins into Strike Plate: Remove the two (2) roll pins from the hardware packet. Insert a roll pin into each of the holes in back of strike. Gently tap into place using a hammer. 5. Secure Strike Plate to the Door Apply the included threadlock compound to the 5/16-18 X 1-3/4” flat head socket screw. Pass the 5/16-18 X 1-3/4” flat head socket screw through the strike plate, two (2) neoprene washers, door and into the sexbolt as illustrated.
Adjustments: 1. Assemble Lock to the Bracket and Adjust: Loosen the two screws securing the mounting bracket to the door frame so that the bracket can move. Slide the lock onto the mounting bracket and test fit against the strike plate with the door closed. Slide the lock so that the entire face makes contact with the strike plate. Mark back edge of mounting bracket at each end and remove the lock from the bracket. Quick Clip 7: Adjustment 2.
3. Drill Frame for Anchor Screws: Using the mounting bracket as a template, drill the four remaining holes in the frame for the anchor screws. Metal Frames: Drill 3/16” diameter holes. Wood Frames: Drill 7/32” diameter holes. 4. Install Anchor Screws: Using a Phillips screwdriver, install the four (4) anchor screws. Metal Frames: Use #12 X 1-1/2” Type A, Phillips Pan Head Screws. Wood Frames: Use #14 X 3” Type A, Pan Head Screws. Page 12 PN# 500-10550 Rev.
Final Installation: 1. Insert the top of the Magnalock chassis at the end of the mounting bracket. Slide the lock chassis to the center of the bracket. The edge of the lock chassis must be flush with the end of the mounting bracket when centered (see inset). Quick Clip 8: Final Installation 2. Using a Phillips screwdriver, install the three (3) 6-32 X 3/4” Phillips pan head screws to secure the lock chassis to the mounting bracket. Page 13 PN# 500-10550 Rev.
Final Wiring 1. Pull wires/cables through the wire feed-through hole(s) that are drilled in the frame. A small screwdriver has been included to help make connections to the terminal blocks as required. The end user and installer are liable for Fire and Building code compliance. 2. The following diagrams show basic wiring configurations for the Magnalock. M670 *VERIFY JP1 JUMPER POSITION FOR NO/NC OPERATION *VERIFY JP1 JUMPER POSITION FOR NO/NC OPERATION M680BD Page 14 PN# 500-10550 Rev.
3. After installation and wiring have been completed, re-install the lock cover through the lock chassis using the two (2) phillips screws removed in the first step. Front View MAGNALOCK MAINTENANCE Visual Inspection Check the rubber washers for elasticity and proper pivoting. Tighten as required. Check for build-up of debris on the Magnalock and strike armature. Check for rust on the Magnalock and strike plate armature. Clean as required.
Troubleshooting Guide: POSSIBLE ISSUES TROUBLESHOOTING TIPS No power or low power Confirm voltage and current at Magnalock to spec (see page 2) Check that the DC Power Source is Full Wave Rectified (Half wave Rectified or AC power is unacceptable) Reduced Holding Force Check strike plate position and orientation Clean surfaces and check for obstructions LED Error Codes: Note LED Jumper J4 must be installed (LED ENABLED) for error codes to be visible CODE STATE SOLUTION SECURE selected color, on con