Programming instructions
Digital Monitoring Products  XR200-485 Programming Guide
14
DEVICE SETUP
XR200-485 Programming Guide  Digital Monitoring Products
15
DEVICE SETUP
Device Setup
4.1 
DEVICE SETUP
  Device Setup
This section allows you to dene the XR200-485/485B panel physical conguration. 
You can install and address up to sixteen supervised devices on the keypad data bus.  
Zones are available only from addresses 1-8. Additionally, certain device functions 
are programmed in address pairs; 1-9, 2-10, 3-11, 4-12, 5-13, 6-14, 7-15, and 8-16. 
These options include Partition (4.4), Access Keypad Reports (6.7), Menu Display 
(9.1), Status List (10.1), Prewarn (13.14), and Presignal (13.17). In each of these 
options, only addresses from 1-8 are programmable. For example, if 1 is selected, 
address 9 is also selected; if address 2 is selected, 10 is also selected.
4.2 
MAX PARTITION:  1
  Maximum Partitions
Enter the maximum number of partitions you want in this system. You can choose 
from 1 to 4. To change the number displayed, press any Select key, enter the 
number of partitions you want to enable, and press COMMAND.
  Changing the number of partitions resets user codes: Whenever you change the 
number of partitions on the panel, all programmed user codes are cleared. The only 
user code available after a partition change is the factory default of 99.
Partitions 
Enabled
Areas Available Users Codes 
Available
User Proles 
Available
1 1 to 8 1 to 999 1 to 99
2
Partition 1: 1 to 8
Partition 2: 1 to 4
Partition 1: Up to 500
Partition 2: Up to 500
Partition 1: Up to 50
Partition 2: Up to 50
3
Partition 1: 1 to 8
Partition 2: 1 to 4
Partition 3: 1 to 4
Partition 1: Up to 400
Partition 2: Up to 300
Partition 3: Up to 300
Partition 1: Up to 40
Partition 2: Up to 30
Partition 3: Up to 30
4
Partition 1: 1 to 8
Partition 2: 1 to 4
Partition 3: 1 to 4
Partition 4: 1 to 4
Partition 1: Up to 400
Partition 2: Up to 200
Partition 3: Up to 200
Partition 4: Up to 200
Partition 1: Up to 40
Partition 2: Up to 20
Partition 3: Up to 20
Partition 4: Up to 20
4.3 
DEVICE NO:-
  Device Number
Enter the device number on the keypad bus you are programming. The keypad bus 
supports up to 16 devices.
4.4 
DEVICE 1:  STNDRD
  Device Type
STD  FIRE    NONE
 STANDARD - The device is either a Security Command keypad, a 711, 714, or 
715 Zone Expander, a 6155LX PIR, 5845LX Glassbreak Detector, or a 733 Wiegand 
Interface Module.
FIRE - The device is an Addressable Fire Alarm Control panel or a Model 630F Remote 
Fire Command Center. 
Note: Devices must be programmed in pairs as mentioned above. For example, if 
device 1 is programmed as FIRE, device 9 must also be programmed as FIRE or NONE.  
Furthermore, if you do not want device 9 to be FIRE, you may use a 733 and it will 
still function. 
NONE - No device is set for this address.
If you entered 2, 3, or 4 in section 4.2 MAX PARTITION, the keypad displays the 
PARTITION NO: prompt. If there is only one partition programmed in section 4.2, the 
keypad does not display the partition assignment prompt.
4.5 
PARTITION NO:  1
  Partition Number
Enter the partition number where the current device being programmed is assigned.  
For systems with more than one partition, press any top row Select key then enter 
1, 2, 3, or 4. Press COMMAND to program the next device.
4.6 
DOOR NAME XX
  Door Name 
The door name displays. To change the name, press any top row Select key then 
enter up to 16 characters for the door name. Press COMMAND to continue device 
setup programming. 