DEVICE SETUP
XR200-485 Programming Guide  Digital Monitoring Products
15
DEVICE SETUP
4.7 
ACCESS - - - - - - - -
  Access Areas
Enter the area numbers (1 to 8 for partition 1 and 1 to 4 for partitions 2, 3, and 4). 
Users must have matching access area numbers assigned to their code to receive 
door access at this device.
If you do not enter any area numbers, all users with Door Access authority will 
receive door access without regard to schedules. If the user code is programmed 
for Anti-Pass YES, then the user is logged into all matching areas. This user is not 
allowed to access these areas again until they have egressed the area. See Egress 
Areas below.
4.8 
EGRESS - - - - - - - -
  Egress Areas
Use this option to detect Anti-passback violations. Anti-passback requires a user to 
properly exit (egress) an area they have previously accessed. If users fail to exit 
through the proper card reader location they are not granted access on their next 
attempt. Enter the area numbers (1 to 8 for partition 1 and 1 to 4 for partitions 2, 
3, and 4). Users must have matching access area numbers assigned to their prole, 
to receive a door access at this device. If the user is programmed for Anti-Pass 
YES, then the user is logged out of all matching areas. This allows the user to again 
access the area. See Access Areas section.
If you do not enter any area numbers, all users with Door Access authority receive 
door access without regard to schedules. If you are not using the Anti-Pass feature 
leave the option blank.
4.9 
STRIKE TIME:  5
  Strike Time
This prompt allows you to enter a door access time during which a keypad or access 
control device relay is activated. Magnetic locks or electric door strikes can be 
connected to the relay and released for the length of time specied here. Enter a 
time between 1 and 250 seconds. The default is 5 seconds.
This prompt also allows you to enter zero to activate the device relay with a toggle 
action. This allows the user to activate or deactivate the device relay each time a 
valid user code is entered. The device relay is activated or deactivated until a user 
code is entered again.
Note: The Request to Exit door access time of a keypad or Model 733 Wiegand 
Interface Module is not affected by this selection. It remains at 5 seconds.
4.10 
FIRE EXIT  NO  YES
  Fire Exit Release
Select YES to allow the door access relay at this address to release whenever Fire 
panic keys are pressed or a Fire or Fire Verify zone alarm is in the Status List. The 
relay is reset whenever a Sensor Reset is performed to remove all Fire and Fire 
Verify zone alarms from the Status List. Select NO to not allow the door access relay 
at this address to release.
4.11 
OUT GROUP NO  YES
  Output Group
Select YES to allow the output group (relays) assigned to the user prole to turn ON 
when the device relay is activated for the programmed strike time. This could be 
used to operate an elevator control. Default is NO. See Section 18.11 User Proles 
in the Appendix of this document for more information about proles. 
4.12 
OVERRIDE NO  YES
  Schedule Override
Use this option to allow door ON/OFF schedules to be overridden by the armed 
condition of the system. Selecting YES causes the on time for a door schedule to be 
ignored when all areas assigned to Access Areas for this device are armed. Should 
any area become disarmed after the door schedule on time, the device output turns 
on. A door output which is on during a disarmed period automatically turns off when 
all access areas assigned to the device become armed, even if the scheduled off 
time has not been reached. This feature can be used to keep doors locked when a 
factory opens late, or is forced to close early, due to a snow storm or other cause. 
Select NO to allow door schedules to operate independent of system armed status.
Note: When OVERRIDE is YES and there are no areas programmed in ACCESS AREAS, 
the door schedule for that device does not work. Either set OVERRIDE to NO or 
enter an area number in ACCESS AREAS. 