Programming instructions
Digital Monitoring Products  XR200-485 Programming Guide
30
AREA INFORMATION
XR200-485 Programming Guide  Digital Monitoring Products
31
AREA INFORMATION 
Area Information
14.1 
AREA INFORMATION
  Area Information
Allows you to assign functions to the different areas within a partition. All non-24-
hour zones must be assigned to an active area. See Zone Information. 
You activate an area by assigning it a name. See Area Name. A name is given to 
each active area in place of a number to assist the user during arming and disarming.
14.2 
PARTITION NO:  1
  Partition Number
Enter the partition number to program. Partition 1 using area arming can have up to 
eight areas on the panel. Partitions 2, 3, and 4 using area arming can each have up 
to four independent areas.
This prompt does not display if you only entered one partition in Device Setup.
14.3 
EXIT DELAY:    45
  Exit Delay
Enter the exit delay time for all Exit type zones in this partition. When the exit 
delay time starts, all activity on that zone and other non-24-hour zone types in the 
area are ignored until the exit delay expires. The keypad displays the countdown. 
If an Exit zone is in a bad condition at the end of the exit delay:
•  the alarm bell sounds for 2 seconds
•  an Exit Error report is sent to the central station receiver
•  the bad Exit zone is force armed
If any other zone type is placed in a bad condition at the end of the exit delay an 
alarm is indicated. The exit delay can be from 1 to 250 seconds. Enter zero to 
disable the Exit Delay feature.
14.4 
BURG BELL OUT:  0
  Burglary Bell Output
Enter the output number (0 to 10, 100 to 299, G1 to G20, or D1 to D16) that turns on 
any time a Burglary type zone in this partition is placed in alarm. The output turns 
off when you disarm the area in which the alarm occurred and no other Burglary 
type zones are in alarm. The output can also be turned off using the Alarm Silence 
option in the User Menu or by entering a user code with the authority to silence 
alarms. The duration of this bell output follows the time entered in the System 
Options/Bell Cutoff Time prompt. See the Output Options - Bell Cutoff Time 
section. If Bell Test is selected YES, the Burglary Bell Output entered here is turned 
on for two seconds each time the system is armed.
14.5 
O/C RPTS  NO  YES
  Opening/Closing Reports
This option allows an Opening report to be sent to the receiver whenever an area 
within this partition is disarmed. A Closing report is also sent to the receiver when 
any area within this partition is armed.
14.6 
CLS CHK  NO  YES
  Closing Check
Select YES to enable the panel to verify that all areas in this partition have been 
armed after temporary or permanent schedules have expired. If the Closing Check 
nds any areas disarmed past the scheduled time, the keypad selected to display 
System Trouble Status displays CLOSING TIME! and emits a steady beep.
If you select YES in the Area Schedules section, the appropriate area name displays 
followed by - LATE. The keypad steady beep is silenced by pressing any top row 
Select key. If the system is not armed or a temporary schedule not entered to 
extend the closing within ten minutes, a Late to Close report is sent to the SCS-1 or 
SCS-1R Receiver if AUTO ARM is NO. See Automatic Arming section. If the area has 
been disarmed outside of any schedule, the closing check sequence occurs one hour 
after the area is disarmed and continues each hour until the area is armed or the 
schedule is extended.