Installation guide
10  LCD Keypad Installation Guide
  LCD Keypad Installation Guide  11
The Keypad Options menu allows you to set the keypad address, select 
Supervised or Unsupervised mode, change the default keypad message, 
selectively enable the 2-button Panic keys, Soft-Shunt, Request-to-Exit, and set 
entry card options. 
Note: All programming options display on all keypads, however, actual 
operation for some programming options is restricted to the listed keypads.
Programming Keypad Options
KPD KPD
OPT DIAG    STOP
 Keypad Options (KPD OPT) 
To program keypad options, press the left Select 
key under KPD OPT. The display changes to 
CURRENT KEYPAD ADDRESS: # #. 
CURRENT KEYPAD
ADDRESS:    01
 Keypad Address
Set the keypad address from 01 to 05 with the 
XRSuper6 and XR20, from 01 to 08 with the XR40, 
XR100 and 01 to 16 with the XR500 Series and 
XR2500F. The factory default address is set at 01. 
To change the current address, press any Select 
key and then enter the new address using the 
appropriate number keys on the keyboard. It is not 
necessary to enter a leading zero for addresses 01 
to 09.
KEYPAD MODE:
*SUP     UNSUP
 Keypad Mode
Conīgure the keypad for either Supervised or 
Unsupervised operation. Keypads with zones 
connected to them must be supervised. Supervised 
keypads cannot share addresses with other 
keypads. 
Unsupervised keypads can operate with other 
unsupervised keypads sharing the same address. 
Zones cannot be used on unsupervised keypads. To 
change the current setting, press the Select key 
under SUP or UNSUP. An asterisk appears next to 
the selected option.
Note: Unsupervised addresses cannot be used when 
Device Fail Output has a programmed value other 
than zero. 