Installation guide
16  LCD Keypad Installation Guide
  LCD Keypad Installation Guide  17
DEGRADED MODE 
RELAY ALWAYS OFF
 Degraded Mode 
  (7063/7063A, 7073/7073A/7163/7173,
   693/793 only)
This option denes the relay action when 
communication with the panel has not occurred 
for ve seconds. Press any top row Select key 
to display CHOOSE ACTION. The default is Relay 
Always Off. 
CHOOSE ACTION
OFF SITE ANY ON
  Choose the Degraded Mode Action required.
Press the rst Select key to choose OFF
[Default] (Relay Always Off) 
  —  The relay does not turn on when any 
    Wiegand string is received. 
    Off does not affect any REX operation. 
Press the second Select key to choose SITE 
(Accept Site Code) 
  —  Door access is granted when the 
    Wiegand site code string received 
    matches any site code programmed at 
    SITE CODE ENTRY. 
    For details refer back to the REQUIRE 
    SITE CODE option. 
Press the third Select key to choose ANY 
(Any Wiegand Read) 
  —  Door access is granted when any 
    Wiegand string is received. 
Press the fourth Select key to choose ON 
(Relay Always On) 
  —  The relay is always on. 
CHOOSE ACTION
LAST
  Press the COMMAND key to display the next 
action. 
Press the rst Select key to choose LAST 
(Keep Last State) 
  —  The relay remains in the same state 
    and does not change when 
    communication is lost. 
After choosing the action, DEGRADED MODE and the 
newly dened action display. Programming is now 
complete. 