AIR-ALARMII SERIES USER’s MANUAL D.I.Y.
© Copyright 2012 This manual is furnished under license and may be used or copied only in accordance with the terms of such license. Except as permitted by such license, no part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or any means, electronic, mechanical, recording, or otherwise, including translation to another language or format, without the prior written permission of SecurityMan.
Warranty Disclaimer SecurityMan Inc, makes no other warranties, express, implied or otherwise, regarding this product, and specifically disclaims any warranty for merchantability or fitness for a particular purpose. The exclusion of implied warranties is not permitted in some states and the exclusions specified herein may not apply to you. This warranty provides you with specific legal rights. There may be other rights that you have which vary from state to state.
Table of Contents Introduction Package Contents Air-AlarmII & Air-AlarmIIB (Standard Kits) Air-AlarmIIE (Economy Kit) Air-AlarmIIDL (Deluxe Kit) Main Features Alarm Host (SM-8088T) Front Panel Back Panel Alarm Host Specifications (SM-8088T) Three types of Defense Line How to change the programming password Programming the Alarm Host (SM-8088T) Operation Understand and Setup Wireless Accessories Wireless Remote Controllers (SM-88X) Wireless Smart Door/Window Sensor (SM-87L) Wireless Doorbell Button (SM-82) W
Introduction SecurityMan Air-AlarmII series is a wireless LED touchpad security alarm system kit for home and business. It is user-friendly and easy to use protecting homes/businesses at a minimum cost of investment. Do-It-Yourself installation and monitoring alarm system without monthly fees is a key benefit for users. The system will alert the owner by phone calls through a series of programmable phone numbers.
Main Features • Easy-to-use and cost-effective D.I.Y.
BACK PANEL Cable Manageme nt Slots Mounting Holes Record remove back cover Play Tel IN Backup Battery ON/OFF Spea ker Power Tel OUT * In off mode, the alarm host will still operate normal if the AC power is connected.
Three types of Defense Line Types of Defense Line and what they mean: 24-hour Defense Line (Zone 1~5): Sensors programmed into any of the 24-Hour defense zones are automatically set on a “24-Hour Monitoring Status”, and usually consist of wireless panic buttons, smoke detectors & gas sensors (N/A). 1st Defense Line (Zone 6~10): Indicates the first defense areas or the perimeter zone (such as doors and windows). This is the perimeter areas where thieves initiate when attempting to break in.
press PRGM + 888 + ENT followed by 11 + ENT. The programming default password is 888 (3 digits long), and 11 is the programming code for 1 minute Delay Time to Arm. Inputting Alarm Telephone Number: PRGM + Password + ENT + XX + ENT + Telephone Number + ENT_ _ XX indicates telephone group number which can be programmed with personal or management center phone number. Depending on the land line service provider a 1 and or area code may be necessary.
FOR MANAGEMENT CENTER USE ONLY: To upload arm/disarm to management center: PRGM + Password + ENT + XX + ENT_ _Enter 50 to disabled upload, enter 51 to enable upload to management center, the default setting is 50 or disable. Leave this disable if management center is not in service. User Code: PRGM + Password + ENT + 80 + ENT + XXXX + ENT_ _ Enter a number between 0000~9999 for XXXX to setup user code for management center. The default is set as random (For Ademco Management Center).
A) Press the number “8” on the phone to extend the time intervals for an additional 20 seconds to enter the listening state. In the listening state the built-in microphone on the alarm host will be active to pick up any sound that takes place near by the alarm host. B) Press the pound “#” button to replay the recorded voice message. C) Press the star “*” button, the host will end/drop the call and stop to dial the next enlisted alarm telephone numbers.
Wireless smart door sensor: Monitor the opening and closing of doors and windows. In the alarm disarm mode, if doors and windows are open and closed, the alarm host will chirp and the status light flashes frequently to alert the doors and windows were opened. This feature requires SM-87L(door/window sensor) and SM-8088T(Alarm Host) as equipped with Air-AlarmII/B package. Wireless doorbell: Wireless doorbell button (SM-82) integrates with security alarm.
Wireless Remote Controllers (SM-88X) Functions/Features: • Used to arm and disarm alarm host. • Emergency button for emergency or panic help. Specifications: • Operating power: 27A 12V Battery (Recommend: alkaline battery) • Wireless Transmitting distance: ≥300ft (in open area) • Service life: ≤2 years Installation and Usage: Makes arming and disarming the alarm host fast and easy. The “AWAY” button is normally used whenever you leave your home or business.
To Cancel: Press PRGM + Password + ENT+ 71 + ENT+ 00 + ENT the alarm host will beep in series then the “ ” light flash once and then turn off to indicate the remote control has been successfully cancelled. Note: The alarm host can only learn 1 remote control at a time, a total of 10 remote controllers can be added to the host. The remote control dedicated programming code is 00. Wireless Smart Door/Window Sensor (SM-87L) Smart * For Mounting Holes, please use screw (C) or adhesive sticker.
• Service life: ≤2 years • Alarm Distance: <4cm Installation and Usage: To install the Smart door/window sensor, mount the magnetic and the emitting of the sensor to the door frame about 5~6 feet above ground. Maker sure the magnetic is installed on the apposite side of the battery compartment of the emitting piece of the Smart sensor. Mount it high enough to prevent children from tampering with the sensor. Use the clear plastic rectangular bracket underlay provided to mount if surface area is un-even.
Disabling Smart Arm: Press PRGM + Password + ENT + 90 + ENT **Implies to zones 06 through 10 only. **Detect the door/window OPEN status alert when attempting to ARM. Another feature that is equipped with the Smart door/window sensor is the Zone Alert feature. The Zone Alert if ON (System Default) send the signal to the alarm host to beep in series to notify the door/window open status and close status.
Adding and Cancelling Smart Door/Window Sensor: To Add: The “ ” light will appear solid blue. Step 1: Press PRGM + Password + ENT + 70 + ENT+ XX + ENT [The XX indicate zone number of the 1st defense line, including zones 06 through 10 ]. Step 2: Triggers the Smart Door/Window magnet twice consecutively, the alarm host will beep in series and the “ ” light flashes five times and then turns off to indicate the magent Smart door/ window sensor has been success fully added.
• Low-battery LED indication Specifications: • • • • Operating power: Li-ion battery (3.7V / 200mA) Charging time: 12 hours Emitting distance: ≥150m (in open area) Service life: ≤3 year Installation and Usage: Install the mounting bracket using the screws provided to a desire location intended for visitors to ring the doorbell. Situate it about 1.4m above the ground is recommended.
Wireless Wide-Angle PIR Motion Sensor (SM-80) * Please use screw (E) to install the bracket (see page26) Functions/Features: • Mainly monitor and control indoor stereoscopic spaces, generally set as a 2nd Defense Line. • When human body enters the detection areas, the motion sensor will transmit the alarm signal to the alarm host. • It is immune to pets; cats, dogs, etc that are less than 10KGS will not cause false alarm.
The PIR (SM-80) sensor featured Zone Alert which send the signal to the alarm host to beep in series notifying there is someone in the front of the motion sensor in alarm Disarm mode. Each time the motion sensor detects movement the alarm host will beep 5 times. By default the Zone Alert feature is set as disable.
Note: The alarm host can only learn 1 wireless device (Magnet Smart Door/Window Sensor) at a time, a total of 4 wireless devices (magnetic sensors) to a zone can be added. For example; for the 1st defense line, if 4 sensors were to be added to zone 06 through zone 10, there would be a total of 20 sensors in all. If 1 device is removed from a zone that contain 4 devices, then all 4 devices in the zone will be removed, and each device will have to be added again by following the “To Add” procedures above.
Adding and Canceling Indoor Siren: To Add: Step 1: Connect the siren to an electrical power outlet and wait for 30 seconds. Step 2: Press the “Learning” button located on the left side of the siren and the siren light will come on. Step 3: Press the “ ” button on the alarm host (remote control not applicable) to sound off the sirens and allow the alarm to siren for 12 seconds.
Functions/Features: • • • • Monitor and control indoor fire risks, for indoor use only, generally set as a 24 hour Defense Line. Replace the battery every 2 years (varies on usage). Usually installed to ceilings of living room, hallways, aisles, etc.
Wireless Outdoor Siren (SM-103, optional) * Please use screw (G) to mount. (see page26) Functions/Features: • • • • • Nice, exquisite, and weatherproof. Micro-computer controller, steady performance and quality. Study up to 10 pieces to a host. Built-in rechargeable battery for backup, automatic switches between AC powers to DC power in cases of emergency outage. Low standby power consumption, low battery voltage LED detection, resumes charging automatically.
(Outdoor/indoor) to secure the outdoor siren with the mounting screw provided and finally plug in the power cord to an electrical power outlet. After pairing the siren to the alarm host and securing it to a fixed location, the siren is ready to received alarming signal from the Air-Alarm host. This siren is rated at 120dB, an ear piercing loud sound that could be heard blocks away.
Functions/Features: • Used for emergency panic, generally set as a 24 hour Defense Line. • Placed under tables, beside bed whenever panic is needed. • Replace battery every 2 years (varies on usage). Specifications: • Operating power: 23A 12V Battery (Recommend: alkaline battery) • Wireless Transmitting distance > 450ft (in open area) • Service life: < 2 year Installation and Usage: Install in living rooms, bedsides, carry along, etc.
Air-AlarmII/B (Standard Kit) Defense Zone Code Chart: Defense Zone Code Defense Zone Type Bypass Zone Delay Time to Alarm 00 —— No No Compatible Accessories Remark Wireless Remote Controller & Wireless Remote Control Up to 10 RC Keypad Wireless Smoke Alarm, 1 to 5 24-hour Defense Line No No Wireless Gas Alarm, & Panic button.
Common Problems and Solutions Problems Possible Cause Solutions The alarm host sounded off immediately after connecting the power The telephone incoming line has not been connected, poor connection or short circuit. Double check, test and secure the incoming telephone line or use a standard phone to test the line to ensure working status. The alarm host cannot record or partially records The Record buttons not pressed down and held while attempting to record, or not held down all the way.
The detecting distance of PIR motion sensor gets shorter The ambient temperature in the detecting area is too high. When the ambient temperature in the detecting area exceeds the human body temperature, the detecting distance will get shorter, it’s normal. The alarm host does not alarm after the new added wireless detector is triggered.
Daily Maintenance and Care This alarm system is hi-tech with outstanding design functionality and sophisticated product features which should be used carefully. To make the alarm system operable long term and prolong the service life; the following are strongly recommended: 1. Install the alarm system and alarm host in dry and well ventilated locations. 2. Do not put the alarm host or any wireless sensors in extreme cold, extreme heat or excessively dusty places.
Frequently Asked Questions Q1: If I have an answering machine turned on will I be able to call in to arm/disarm the host? A1: No, please be sure to turn off the answering machine on the telephone for the alarm host to be able to receive incoming calls.
Q9: Do I need to add each of the wireless devices that comes with the kit to the Alarm Host? A9: No, each wireless device inside each Air-Alarm kits is already added by default. Q10: How can I clear the enlisted telephone numbers from the list? A10: To clear the enlisted telephone numbers press PRGM+password+ENT+01 (01~05 group no.)+ENT+ENT Or simply add the enlisted telephone numbers to the same group to override the old.
www.securitymaninc.