Air-Alarm1 D.I.Y.
Copyright Notice This manual is furnished under license and may be used or copied only in accordance with the terms of such license. Except as permitted by such license, no part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or any means, electronic, mechanical. Recording, or otherwise, including translation to another language or format, without the prior written permission of SecurityMan.
Table of Contents Introduction 1 Package Contents 1 Main Features 1 Alarm Host (SM-8088E) 2 Alarm Host Specifications (SM-8088E) 3 Three types of Defense Line 3 Programming the Alarm Host (SM-8088E) 4 To Setup User Code (For Ademco Managemant Center) 5 How to change the programming password 5 Operation 6 Understand and Setup Wireless Accessories 8 Wireless Remote Controllers (SM-88X) 8 Wireless Door/Window Sensor (SM-87B) 9 Wireless Wide-Angle PIR Motion Sensor (SM-80) 11 Wireles
Introduction SecurityMan Air-Alarm1 is a state-of-the-art wireless alarm system kit for homes and businesses. It is user-friendly and easy to use protecting homes/ businesses at a minimum cost of investment. Do-It-Yourself installation and monitoring alarm system without monthly fees is a key benefit for users. The system will alert by phone calls to owner through a series of enlisted phone numbers. The owner can then dial into the host to arm or disarm the alarm by using the phone’s numeric keypad.
• Programmable silent alarm or audible alarm. • Recordable alarm voice message (up to 9 seconds record time). • Telephone line disconnection alarm sound every 5 seconds. • Smart 3 defense lines configuration-1st defense line is the perimeter, 2nd defense line for in-room, & 24-hour defense line. • Internal rechargeable backup battery in alarm host lasts up to 8 hours. • Battery included for remote controllers, wireless door sensor, and wireless motion sensor last up to 2 years. • Programmable password.
Alarm Host Specifications (SM-8088E) • Operating power: 9-15VDC • Static current: ≤ 60mA • Alarm current: ≤ 380mA • Operating environment: Temperature: -10° ~ 50°C Humidity: <80% • Maximum available quantity of remote controllers: 8 PCS • Maximum available quantity of wireless sensors: 60 PCS • Dimensions: 180X120X38 (mm) • Rechargeable battery: Ni-Mh(4.
Programming the Alarm Host (SM-8088E) _Function_:_Operation__Operation Explanation Notes: 1. The alarm host will automatically exit from the programming status if inactive for 20 seconds. 2. Programming is effective after _SET+Password+ENT_, use ESC button to go to previous step. 3. The alarm host will beep in series to indicate the operation is successful and beep once to indicate operation failure.
_Alarm Sound for 1st and 2nd defense line_: _XX + ENT__ Enter 40 for XX to disable alarm sound for 1st & 2nd defense line, enter 41 to enable Audible alarm, the default is 41. When the Alarm Sound is disabled or set to 40; the alarm host will operate normal and will continues to dial the enlisted phone numbers upon alarm trigger. _Telephone Disconnection Alarm_: _XX + ENT__ Enter 60 for XX to disable Telephone Disconnect Alarm, enter 61 to enable Telephone Disconnect Alarm, the default is 61.
Operation To Record a voice message greeting: Slide the switch on the left side of the alarm host to the RECORD ON position, press and hold the microphone button, speak close (6”) into the rear speaker of the host, and then release the microphone button when finished with your voice message greeting. Voice message greetings can be anywhere between 0~9 seconds long.
C) Press the star “*” button, the host will end/drop the call and stop to dial the next enlisted alarm telephone numbers. After the “*“ is pressed; the alarm host will resume to be armed Note: the is required in order to stop the alarm host from continuing to dial the next enlisted telephone numbers. D) Hang up the telephone without any command input, the host will end the call and automatically continues to dial the next enlisted alarm telephone numbers.
Understand and Setup Wireless Accessories Please note that all the devices included with the Air-Alarm1 kit is paired to the Alarm Host (panel) by default. If sensing devices does not trigger the Alarm Host, please reference to the “To Add:” instructions in the user’s manual to add the wireless devices accordingly. All newly add-on sensing devices is required to be pair with the Alarm Host. Wireless Remote Controllers (SM-88X) Functions/Features: • Used to arm & disarm alarm host.
• Press the “HOME” button to part arm or 1st defense line enable to protect the perimeters of your home at night time before going to sleep. • Please replace the battery within 2 years of usage or any time when it becomes less sensitive or has a shorter controlling distance. Adding & Cancelling Remote Controllers. To Add: • Press_SET + Password + ENT_then. • _70 + ENT+ 00 + ENT the “Learn” light will appear solid red.
Functions/Features: • Mainly detect open/close states of doors and windows, generally set as a 1st Defense Line or perimeters. • If any doors or windows are opened, it will transmit the alarm signal to notify the alarm host.
Wireless Wide-Angle PIR Motion Sensor (SM-80) * Please use screw (E) to install the bracket (see page22) Functions/Features: • Mainly monitor and control indoor stereoscopic spaces, generally set as a 2nd Defense Line. • When human body enters the detection areas, the motion sensor will transmit the alarm signal to the alarm host. • It is immune to pets; cats, dogs, etc that are less than 10KGS will not cause false alarm.
Installation and Usage • Mount the bracket to a desired wall surface, location, or corner at a height of about 6ft to 7ft above the ground. • Open the sensor cover and connect a 9VDC battery. Next, refers to the diagrams above to adjust and select the Jumper Line timer between 5S or 5MIN for the motion sensor to detect once every 5 seconds or the sensor to detect once every 5 minutes. Recommended to use “5S” default “setting for normal use.
Wireless Indoor Siren (SM-103W) Functions/ Features: • Wireless receiving indoor alarm siren, spot alarm sound and flashes • Plugs into wall outlets, for indoor use only. Specifications: • Operating Power: 100—240VAC • Wireless Receiving distance:≥300 ft (In open area ) • Siren Sound 105dB Installation and Usage: • Plug the wireless indoor siren into a power outlet. • Recommendated to install 4~5ft high from the ground.
keypad by pressing _ESC/Disarm + programming password + ENT_, the alarm host will beep twice to indicate the indoor siren has been successfully disarmed. • The light on the siren will flash 5 times to indicate the indoor siren has been successfully added. To Cancel: • After connecting the siren to the power outlet, press and hold the “Learn” button located on the left side of the siren for 5 seconds, the light on the siren will flash once to indicate the indoor siren has been successfully cancelled.
Specifications: • Operating power: 9V Battery (Recommend: alkaline battery • Wireless Transmitting distance: ≥300ft (in open area) • Service life: ≤2 years • Monitor volume: 480ft3 Adding and Cancelling Smoke Alarm To Add: • Press_SET + Password + ENT_then. • _70 + ENT+ XX + ENT The “Learn” light will appear solid red. Note: The “XX” indicate group number of the 24 hour defense zones, including zone 01 through zone 05.
Functions/Features: • Nice, exquisite and weatherproof. • Micro-computer controller, steady performance and quality. • Study up to 10 pieces to a host. • Built - in rechargeable battery for backup, automatic switches between AC powers to DC power in cases of emergency outage. • Low standby power consumption, low battery voltage LED detection, resumes charging automatically.
• Alarm Host: Press “ ” emergency button on the alarm host to sound off the alarm and then disarm the alarm by using the _ESC/Disarm + programming password + ENT_, the alarm host will beep twice to indicate the outdoor siren has been successfully disarmed • The light on the siren will then flash 5 times to indicate the outdoor siren has been successfully added. Note: One siren can be studied at a time, up to 10 wireless alarm sirens to a host.
Installation and usage • Installed in living rooms, bedsides, carry along, etc. • For emergency use, scared away intruders; sends out emergency signal to alarm host to sound off the siren(s). This is a 24 hour standby zone for panic or emergency use only. • Please change the battery when the signal distances become shorter or every 2 years. Adding and Cancelling Panic Button To Add: • Press_SET + Password + ENT_then. • _70 + ENT+ XX + ENT The “Learn” light will appear solid red.
Air-Alarm1 Defense Zone Code Chart: Defense Zone Code Defense Zone Type Bypass Zone Delay Time to Alarm 00 —— No No Compatible Accessories Remark Wireless Remote Controller & Wireless Remote Control Up to 8 RC Keypad Wireless Smoke Alarm, 1 to 5 24-hour Defense Line No No Wireless Gas Alarm, & Panic button.
Common Problems and Solutions Problems Possible Cause Solutions The alarm host sounded off immediately after connecting the power The telephone incoming line has not been connected, poor connection or short circuit. Double check, test and secure the incoming telephone line or use a standard phone to test the line to ensure working status. The alarm host cannot record or partially records The record switch is not turned on.
The detecting distance of PIR motion sensor gets shorter The ambient temperature in the detecting area is too high. When the ambient temperature in the detecting area exceeds the human body temperature, the detecting distance will get shorter, it’s normal. The alarm host does not alarm after the new added wireless detector is triggered.
Daily Maintenance and Care This alarm system is hi-tech with outstanding design functionality and sophisticated product features which should be used carefully. To make the alarm system operable long term and prolong the service life; the following are strongly recommended: 1. Install the alarm system and alarm host in dry and well ventilated locations. 2. Do not put the alarm host or any wireless sensors in extreme cold, extreme heat or excessively dusty places.
Air-Alarm1 Frequently Asked Questions Q1: If I have an answering machine turned on will I be able to call in to arm/disarm the host? A1: No, please be sure to turn off the answering machine on the telephone for the alarm host to be able to receive incoming calls.
Q10: How can I clear the enlisted telephone numbers from the list? A10: To clear the enlisted telephone numbers press; SET+password+ENT+01 (01~05 group no.)+ENT+ENT Or simply add the enlisted telephone numbers to the same group to override the old.