User manual
Dokument: 03 2012 LC 1 Short E 01 
Security & Electronic Technology 
Aumühlweg 3/1 
A-2544 Leobersdorf – Austria
- Button =  restart the Software 
- Button = wake up device 
go from one function to the other 
- Button = Increment the flashing digit launch manual  
measurement
1 
Press  for more than 3 seconds
1.1 
Select the tank type
1 = rectangular 2 = horizontal cylindrical 3 = vertical cylindrical 
1.2 
Please refer to the dimension indications of your 
Tank !!! 
Volume :  xxxx 
 Height :   xxx
1.3 
Enter the dimensions of tank type 2 
Please refer to the dimension indications of your 
Tank !!! 
Volume :  xxxx
Diameter :  xxx 
1.4 
Power save mode 
0 = Display OFF in sleeping mode 
1 = Display ON in sleeping mode 
1.5 
Offset 
Enter the distance from the sensor to the liquid in cm 
(when the tank is full) 
Offset = xx 
2 
Put the LC100 in the tank inlet 
2.1 
Start measurement
Press  The display shows for 6 seconds the installed SW- 
Version and makes then a first measurement ; from now on the  
LC100 makes a measurement every 23 h 45 minutes ! 
2.2 
Sleeping Mode 
If the buttons are during 35” inactive, the LC100 goes into the  
sleeping mode 
3 
Press  >>> wake up ! 
Press  >>> make measurement 
(this measurement is not used for statistical data) 
4 
Press  >>> wake up !  % & volume 
Press  >>> liters 
Press  >>> percentage 
Press  >>> empty volume in liters 
Press  >>> distance in cm 
Press  >>> average consumption “last 5 days”  
Press  >>> remaining days  
Press  >>> Error Codes 
Error Codes 
0 = LC100 OK 
1 = Prgrm.-Error 
2 = measurement incorrect 
3 = distance unlogical to settings 
4 = display overflow 
Batt.low =„b“on default display