Model: SESB-250V-16A
Part number: 535742
(Rail Adapter) 535742-02
Voltage [AC]: 230 V +-10%
Rated current [AC]: 16 A
Frequency [Hz]: 50/60
Normal power output [VA]: 3500
Ambient operating temperature (ta) [°C]: 40
Integrated temperature fuse: 128°C / 16A (not replaceable)
Max. switching frequency: 1 x per minute
Phase angle (dimmer): just on one load side permitted!
The switching operation only takes place before the inrusch current limiter!
Wiring diagram:
Only restrictedly suitable for
ohmic and capacitive burdens
NTC- resistance
Recommended max. impulse peak:
E/Joule 90
Destroyed by impulse:
E/Joule 180
Sign: CE
Type: Plastic chassis black (ABS) for wall assembly or rail assembly
Connections: Screw terminals 2,50 mm²
Protection class:
Open for SK II prepared
IP classification: IP 00
Optional accessory:
Rail Adapter (important: degreasing of the adhesive surface on the chassis!)
Dimensions: Length = 68 mm (complete with flap)
Width = 57 mm (without Rail Adapter)
Height = 25 mm
Weight: 0,060 kg
Inrush current limiter for Toroidal Transformers SESB-250V-16A
Data sheet
N
LOAD
Grid
230V / 50Hz
L
N
NTC
K1
128 °C
Switching delay K1
(t > 300 ms)
Photo: SESB-250V-16A (with Rail Adapter)
www.sedlbauer.de