Instructions / Assembly

26
|
SEDONA CARE & USE/INSTALLATION
The grill is factory
set to use either
propane (LP) or
natural gas (NAT).
It is critical that the
gas you use match-
es that which the
grill was set up for.
You can verify that by checking the rating plate.
The rating plate is located in one or more of the following
places:
•Attached to the underside of the drip tray
•On the heat shield behind the front panel
Ensure that the gas supplied meets with the minimum
pressure requirements. Do not operate the grill on any gas
other than that for which the grill has been set.
Fuel WC Max Inlet WC Min Under Full
Load
Nat Gas 7 in 4 in
LP 14 in 11 in
Water Column Requirements
Both the regulator and the manifold orifices have been
tuned for the type of gas specified on the rating plate.
All installation and all installation parts must conform
to local codes with the National Electrical Code, ANSI
Z223.1/NFPA 70 latest edition and the National Fuel
Gas Code, ANSI Z223.1/NFPA 54 in the U.S and CGA-
B149.1/.2 in Canada.
Canadian installations must conform to CGA-B149.1/.2
natural gas/propane installation code. (Canada)
NATURAL GAS
It is recommended that only qualified professionals per-
form the required plumbing on this product.
To ensure satisfactory performance, the gas supply line
GaS connectionS
TANK
GRILL ISLAND
GRILL ISLAND
TYPICAL
BOTTOM
CONNECTION
TYPICAL BACK OF GRILL
CONNECTION
SUPPLIED LP
BRASS FITTING*
ALTERNATE LOCATION
SUPPLIED LP
BRASS FITTING*
SUPPLIED LP HOSE
WITH REGULATOR
* LEAK TEST HERE
LEAK TEST*
BOTTLED LP HOOK-UP
2 Typical LP Bottle
Installations
NATURAL GAS HOOK-UP
3 Typical Natural Gas
Installations
GRILL ISLAND
GRILL ISLAND
INSTALLER SUPPLIED
GAS SHUT-OFF VALVE
(MUST BE IN ACCESSIBLE
LOCATION)*
TYPICAL
BOTTOM
CONNECTION
TYPICAL
BACK OF
GRILL
CONNECTION
TYPICAL BACK
OF ISLAND
CONNECTION
SUPPLIED NATURAL GAS
REGULATOR- PRE-SET
AT 4" W.C.*
INSTALLER
SHUT-OFF VALVE
SUPPLIED GAS
(MUST BE IN
ACCESSIBLE
LOCATION)*
INSTALLER SUPPLIED
GAS SHUT-OFF
VALVE (MUST BE
IN ACCESSIBLE
LOCATION)*
SUPPLIED NATURAL
GAS REGULATOR -
PRE-SET AT 4" W.C.*
SUPPLIED
NATURAL GAS
REGULATOR -
PRE-SET AT
4" W.C.*
SUPPLIED STREET
ELBOW*
SUPPLIED STREET
ELBOW*
SUPPLIED
COUPLER
EXTRA 1/2"
COUPLER
REQ’D HERE*
SUPPLIED 6" NIPPLE
SUPPLIED 6"
NIPPLE
SUPPLIED 6" NIPPLE
* LEAK TEST HERE
Never connect a gas line directly to the grill. A
pressure regulator must be installed on all gas
equipment. All local codes require it and Lynx supplies
the correct regulator with your grill. Removing or
failing to install the pressure regulator can result
in fire and serious personal injury and will void the
warranty.
WARNING
The Rating plate lists serial numbers, model numbers
and gas type. This one is underneath the drip tray.