SEDONA by LYNX™ VENT HOOD CARE & USE/INSTALLATION 1
WARNINGS WARNINGS and CAUTIONS: Must be followed carefully to avoid personal injury, damage or incorrect installation. TIPS: Contains helpful information to facillitate installation. WARNING READ THIS MANUAL CAREFULLY and completely before using your vent hood to reduce the risk of: 1. 2. 3. 4. Fire Electric Shock Personal Injury Unapproved installation THIS PRODUCT IS DESIGNED FOR OUTDOOR USE ONLY.
BEFORE YOU START TO REDUCE THE RISK OF A BBQ TOP GREASE FIRE: a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. b) Always turn hood ON when cooking at high heat or when flambéing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambe’). c) Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter. d) Use proper pan size.
EXTERIOR DIMENSIONS INSTALLER: Read these instructions carefully before starting installation. Please leave these instructions with the homeowner. HOMEOWNER: Please retain these instructions for future use Exterior Dimensions Width D Height E Depth F 36” 24” 32” 42” 24” 32” 48” 24” 32” ” 10 ” 15 2” 2 1/ ” /4 2 1/ 2” 3 8” 24” E ” 36”, 32 42”, D 48” F Exterior Dimensions INSTALLATION PREPARATION The Sedona by Lynx™ vent hoods are designed for outdoor use.
INSTALLING THE VENT HOOD WARNING To Reduce The Risk Of Fire, Electric Shock, Or Injury To Persons, Observe The Following: a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards. b) Sufficient air is needed for proper combustion and exhausting of gasses through the flue (chimney) of fuel burning equipment to prevent back drafting.
INSTALLING THE VENT HOOD...continued All dimensions are nominal +/- 1/8”l ” 10 ” 15 2” 2 1/ 2 1/ 2” ” /4 Note- Two additional electrical holes located on the back of the unit (not shown). Approximately 3/4" from the top and 2 1/2" from the sides.
ELECTRICAL CONNECTIONS WARNING • The following are Manufacturer’s Suggestions. Always Observe Local Building Codes. Hoods installed in custom canopies constructed of combustible materials should be installed with the combustible material structure a minimum of 36” above the cooking surface. Hoods installed in custom canopies constructed of non-combustible materials, should be installed with the non-combustible material structure a minimum of 30” above the cooking surface.
SECURING THE HOOD MOUNTING HOLES: Because the Sedona by Lynx™ Vent Hood was designed for all applications, no mounting holes have been pre-drilled. This allows for custom applications for mounting. The hood should be attached to the framing through the top and back, whenever possible. Remove the filters. Mark and drill screw holes through the hood as required. Secure the hood by driving screws (provided by others) through the screw holes.
CARE AND USE...continued If a commercially available stainless steel cleaner is used, it is important to read the labels for chlorine compounds. Chlorine is a corrosive substance, DO NOT USE. Follow polish manufacturer’s instructions. HALOGEN LIGHT BULBS: Hoods are designed for halogen light bulbs (PAR20). They can be purchased at most home improvement and/or grocery stores.
CARE AND USE...continued Always run ventilator ducts to the outdoors. DO NOT terminate a duct into an attic, basement, garage, crawl space under a house, a chimney, other ducting or an enclosed room. 4. Dampers IMPORTANT: DO NOT USE ANY TYPE OF DAMPER IN A VENT HOOD APPLICATION. In ventilation systems utilizing a roof cap or wall cap with a built-in damper, remove it.
CARE AND USE...continued 7. Duct Sizing Chart and Area Calculations Ventilator Discharge Port Types & Sizes Duct Type Required Duct Size (in Square Inches) Minimum Discharge Size of Roofcap or Wallcap Outside Opening 6” Diameter, Round 28.3” 6” Round Metal Duct 28.3” 28.3” 7” Diameter, Round 38.5” 7” Round Metal Duct 38.5” 38.5” 8” Diameter, Round 50.25” 8” Round Metal Duct or 6” x 9” Rectangular Metal Duct 50.25” 54” 50.25” 54” 10” Diameter, Round 78.5” 10” Round Metal Duct 78.
ROOF CAP DRAWING ” 11 12” A ” 24” *Required dimensions for roof cap - Minimizes static pressure and maximizes air flow to ensure optimum performance of your Sedona by Lynx™ product.
LYNX LIMITED WARRANTY I. Limited Three-Year Warranty The stainless steel housing is warranted to be free from defects in material and workmanship when subjected to normal domestic use and service for three years from the date of purchase for the original purchaser. This warranty excludes surface corrosion, scratches, and discoloration which may occur during regular use. This warranty is limited to the replacement of the defective parts, with the owner paying all other cost including labor. II.
CONTACTING LYNX CUSTOMER CARE Before calling Lynx Customer Care, please make sure you have the following information: • Model number • Date of purchase • Proof of purchase by the original owner • Serial number The serial number can be located interior right hand wall of the vent hood, below the wiring diagram. For warranty service, contact the Lynx Customer Care Department for an authorized service agent near you at: (888) 289-5969 www.lynxgrills.com Your satisfaction is of the utmost importance to us.
EXPLODED VIEW/PARTS 1 2 3 8 4 7 5 6 ITEM PART NO. 36446 1 2 36447 3 36448 4 36449 5 36450 36453 6 7 36452 8 36451 DESCRIPTION QTY.
PRODUCT DIMENSIONS 16 | SEDONA BY LYNX™ VENT HOOD CARE & USE/INSTALLATION
PRODUCT DIMENSIONS SEDONA BY LYNX™ VENT HOOD CARE & USE/INSTALLATION | 17
PRODUCT DIMENSIONS 18 | SEDONA BY LYNX™ VENT HOOD CARE & USE/INSTALLATION
The best outdoor kitchen products come from: Lynx Grills, Inc. 7300 Flores Street Downey, CA 90242 Service: (888)-289-5969 Fax: (562) 299-6978 www.lynxgrills.