User Manual TriSource10 dp Version 4.3 29.03.
TriSource10 dp 1 1 Contents Contents 1 Contents .......................................................................................................................... 2 2 Foreword .......................................................................................................................... 3 3 Safety instructions ......................................................................................................... 4 4 Connectors/Indicators ......................................
TriSource10 dp 2 2 Foreword Foreword The TriSource 10 dp is a loudspeaker box that has been specially designed for applications in combination with large-format video displays, in application where very high sound quality in combination with a long throw is required. It features digital amplifier electronics with 280 Watt + 175 Watt of power @ 4 ohms (AES) and DSP controller. Various pre-configured presets and volume settings are available for selection.
TriSource10 dp 3 3 Safety instructions Safety instructions Acoustic Even a low input level can result in a sound pressure level at the loudspeaker which can be damaging to your hearing. Do not remain in close proximity to the loudspeaker when it is being operated. Use hearing protection. Observe all relevant Health and Safety and Environmental Protection regulations. Mechanical Movable parts and falling objects during installation and de-rigging can cause serious injury.
TriSource10 dp 3 Safety instructions If the loudspeaker is connected to a power source in which the voltage is too high, a protective mechanism is triggered which reliably safeguards the amplifier module and DSP. Once triggered, the protection must be renewed by a qualified service technician. Never open the housing. There are no user serviceable parts inside. Do not expose the loudspeaker to rain, and avoid operating in environments below -5° C or above 40° C.
TriSource10 dp 4 4 Connectors/Indicators Connectors/Indicators 4.
TriSource10 dp 4 Connectors/Indicators 4.2 Connectors XLR socket (1) The TriSource 10 dp should be connected with a standard symmetrically wired XLR cable if the audio transmission is analogue. To connect the input signal to further devices, use the male XLR Loop thru connector. To obtain full power performance from the system, the signal source should be able to provide a minimum of 6 dBu distortion free output voltage.
TriSource10 dp 4 Connectors/Indicators 4.3 Controls Mode button: Switch between the modes Status / Level and Presets. Set button: Set various values and Mute on/off. 4.4 Status indication Mute LED: Lights red when the system is muted (press the Set button in Status Mode), or in technically critical conditions. Limit LED: Lights yellow when the limiter is limiting one or more amplifier channels. Signal LED: Lights green when a signal of more than -20 dBu is present.
TriSource10 dp 5 5 Operation Operation 5.1 Starting up When the system is switched on, it retains the settings from the previous usage. This also applies to the Bank selection. The system is then in the Status Mode. If the red Mute LED is lit as a result of the previous setting, no signal will be passed. Pressing the Set button once will un-mute the system. The Mute LED will go off, and signal will be passed. 5.
TriSource10 dp 5 Operation 5.3 Setting level After switching on and starting up, the TriSource 10 dp is in Status Mode. Pressing the Mode button once selects the Level Mode, in which you can adjust the output volume in 3 dB steps. Seven different values between +6 dB and -12 dB are available, with 0 dB being the standard setting. The setting is made using the Set button.
TriSource10 dp 5 Operation The following representations show examples of settings: The preset “Flat” is active. The preset “Low-Boost” is active. The Soft Mode is switched on. 5.4.1 Preset Bank 1 – Free-Standing (Default Settings) This Preset Bank is to be selected when the TriSource 10 dp is located free-standing in the room or is mounted directly next to a video display and there are no adjacent, acoustically hard reflection surfaces.
TriSource10 dp 5.4.2 5 Operation Preset Bank 2 – On-Wall-Mounting This Preset Bank is to be selected when the TriSource 10 dp is mounted directly on a wall. The presets are optimized in such a way that the mounting wall behind the TriSource 10 dp is regarded as a acoustically hard reflection surface. Flat: Preset for single application without any additional subwoofer. HP: Flat preset with a higher cut-off frequency for the high-pass filter for combination with a subwoofer.
TriSource10 dp 5.4.3 5 Operation Preset Bank 3 – In-Wall-Mounting This Preset Bank is to be selected when the TriSource 10 dp is mounted directly in a wall. The presets are optimized in such a way that the mounting wall besides the TriSource 10 dp is regarded as a acoustically hard reflection surface. Flat: Preset for single application without any additional subwoofer. HP: Flat preset with a higher cut-off frequency for the high-pass filter for combination with a subwoofer.
TriSource10 dp 5 Operation 5.5 Reprogramming of dp-speakers with preset audio files By default, the built-in DSP controller is in a default configuration state that conforms to the description in the User Manual. The installation of special presets on the DSP controller can be done by the user himself, since only a special preset audio file must be loaded. The programming of these audio files via the LPI (Loudspeaker Programming Interface) can only be done by the manufacturer.
TriSource10 dp 6 6 Technical specifications Technical specifications Speaker Components 2x5“ Nd (1,5“ VC) / 3x1“ Nd (1,1“ VC) Description Multi Media Column Amp Power LF: 280 W AES / 110-230 V HF: 175 W AES / 110-230 V Rated Current 0,2 A @ 230 V SPL (Peak @ 1m) Max. Input Signal 118 dB DSP AD / DA Latency Usable Range (-6dB) Tuning Frequency (excursion minimum) X - Overpoint (acoustical) HDLM FPGA Processing 32 bit floating point Coverage (horizontal / vertical) 100° x 25° Max.
TriSource10 dp 7 7 Declaration of conformity Declaration of conformity EU Declaration of conformity This product TriSource10 dp confirms to the following EU guidelines, including any additions: 2006/95/EG, Low Voltage 2004/108/EG, Electromagnetic Compatibility (Locations: Appendix 1, Paragraph 1, a and b) The following standards have been applied: DIN EN 60065 DIN EN 55103-1:1996, classes E1 to E4 DIN EN 55103-2:1996, classes E1 to E4 Declared by: Winfried Seeburg, SEEBURG acoust
Benutzerhandbuch / User Manual Irrtum bei Beschreibung sowie technische Änderungen vorbehalten. Alle SEEBURG acoustic line Produkte sind nur für den gewerblichen Einsatz bestimmt. All specifications are current at the time of publishing but are subject to change. SEEBURG acoustic line GmbH Auweg 32 D-089250 Senden-Freudenegg Fon: +49 (0)7307 97 00- 0 Fax: +49 (0)7307 97 00- 29 www.seeburg.com info@seeburg.