At the “Menu Settings” screen use the navigation keys or the toggle dial to place
the highlight bar on item MuxBus Sensor Setup.
1. New system installation: Place the highlight bar on “Auto Detect”. Press
“Install”.
5.4.1 MUXBUS Sensor Settings and Installation
2. Plug in the sensors in the order
listed on the menu. Different sensors
have different types and cannot be
learned to the wrong location but
the rst fan sensor plugged in will be
assigned to Fan 1. The rst bin level
sensor plugged in will be learned to
Bin 1, etc. The speed, pressure, and
ow sensors all use the same type
sensor code so the rst one plugged
in will be the speed sensor, etc.
3. Add a sensor: Individual sensors
can be added to the MuxBus system
at any time. Place the highlight bar on
the sensor you want to add (Fan 1 in
the example) and press install. Then
plug in the sensor. Multiple sensors
can also be added using this method
but you need to position the highlight
bar on each new sensor and press “In-
stall” before plugging in each sensor.