Datasheet

THERMOPILE
OTP-538U
http://www.orisystech.com
3 / 7
1. General Characteristics
1.1 Absolute Maximum Rating
Table 1: Absolute maximum rating
Parameter Min. Typ. Max. Unit
Ambient Operating Temperature -20 100
Storage Temperature -40 100
1.2 Handling Guidelines
Stresses above the absolute maximum ratings may cause damages to the device.
Do not expose the sensor to aggressive detergents such as Freon, Trichloroethylene, etc.
Avoid touching or cleaning of the window. If necessary, do cleaning only very carefully with alcohol and
cotton swab.
Hand soldering and wave soldering may be applied by a maximum temperature of 260° C for a dwell time
less than 10 s. Reflow soldering is not recommended.
2. Device Characteristics
2.1 Device Descriptions
The materials of OTP-538U are lead-free and fully complied with the RoHS regulations.
Table 2: Device characteristics
Parameter Description
Cap Metal cap with integrated IR window
Header TO 46
Leads (3 isolated + 1 ground) pins with solderable gold coating
Filter Si-based IR filter
Insulation gas sealing The sensor is sealed hermetically in a nitrogen environment.
2.2 Sensor Characteristics
Table 3: Thermopile sensor characteristics
Parameter Min Typ Max Unit Conditions
Output Voltage 0.77 1.44 mV
T
amb.
=25
T
obj.
=50
Sensitivity 70 85 100 V/W *
TC of sensitivity 0.10 0.11 0.12 %/K Typical
Sensitivity area in
diameter
--- 545 ---
μm
Resistance of thermopile 50 65 80
KΩ 25
TC of resistance --- 0.09 --- %/K Typical
Time constant --- 16 --- ms *
Noise voltage 28 32 36 nV/Hz
1/2
NEP 0.28 0.36 0.48 nW/Hz
1/2
Normalized detectivity (D*) 1.0*10
8
1.3*10
8
1.7*10
8
cm*Hz
1/2
/W *
Notes:
*
All optical performances are measured at 1 Hz chopper frequency using a blackbody
radiator of 500K temperature with filtered spectrum ranging from 5 to 14
μ
m.
Distance between packaged thermopile and blackbody is 11cm.