Datasheet

DocID023312 Rev 2 11/52
LSM303D Module specifications
52
2.2 Temperature sensor characteristics
@ Vdd = 2.5 V, T = 25 °C unless otherwise noted
(b)
.
M_CAS Magnetic cross-axis sensitivity
Cross field = 0.5 gauss
Applied = ±3 gauss
±1
%FS/
gauss
M_EF Maximum exposed field
No permanent effect on sensor
performance
10000 gauss
M_DF Magnetic disturbance field
Sensitivity starts to degrade.
Automatic S/R pulse restores
the sensitivity
(5)
20 gauss
LA_ST
Linear acceleration self-test
positive difference
(6)
±2 g range, X-, Y-axis
AST = 1 see Table 37
70
1700
mg
±2 g range, Z-axis
AST = 1 see Table 37
70
1700
Top Operating temperature range -40 +85 °C
1. Typical specifications are not guaranteed.
2. Verified by wafer level test and measurement of initial offset and sensitivity.
3. Typical zero-g level offset value after MSL3 preconditioning.
4. Offset can be eliminated by enabling the built-in high-pass filter.
5. Set/reset pulse is automatically applied at each conversion cycle.
6.
“Self-test output change” is defined as: OUTPUT[mg]
(CTRL2 AST bit =1)
- OUTPUT[mg]
(
CTRL2 AST bit =0
)
.
Table 3. Sensor characteristics (continued)
Symbol Parameter Test conditions Min. Typ.
(1)
Max. Unit
b. The product is factory calibrated at 2.5 V.
Table 4. Temperature sensor characteristics
Symbol Parameter Test conditions Min. Typ.
(1)
Max. Unit
TSDr
Temperature sensor output
change vs. temperature
-
8 LSB/°C
TODR Temperature refresh rate
M_ODR
[2:0]
(2)
Hz
Top Operating temperature range -40 +85 °C
1. Typical specifications are not guaranteed.
2. Refer to Table 47: Magnetic data rate configuration.