Datasheet

SARA-R4/N4 series-AT Commands Manual
UBX-17003787 - R09
13Packet switched data services
Page 143 of 307
The configuration will be effective at the next power on.
Only one PDP profile can be set using this command.
13.17.2Syntax
Type Syntax Response Example
Set AT+UDCONF=76,<cid>,<Data_Flag> OK AT+UDCONF=76,1,0
OK
Read AT+UDCONF=76 +UDCONF: 76,<cid>,<Data_Flag>
OK
AT+UDCONF=76
+UDCONF: 76,1,0
OK
13.17.3Defined values
Parameter Type Description
<cid> Number See <cid>.
<Data_Flag> Number PDP data configuration when roaming:
0 (default value): data enabled when roaming
1: data disabled when roaming
13.17.4Notes
SARA-R4 / SARA-N4
Set the <Data_Flag> parameter before to read it.