User Manual
 2012-2017 Microchip Technology Inc. Advance Information DS40001667E-page 27
MGC3030/3130
FIGURE 5-1: GESTURE PORT MAPPING
The Colibri Suite can generate up to twelve event
outputs which can be mapped to any EIO (1, 2, 3, 6 or
7). It is also possible to map more than one event
output by one EIO.
EventOutput1..12
To EIOs
Gesture Selection 
[0:2]
Electrode Selection 
[0:2]
Gesture
Wake-up after Approach Detection
Action Selection 
[0:2]
EventInput 
Selection [0:1]
Sensor Touch
Flick West -> East
Flick East -> West
Flick North -> South
Flick South -> North
Circle ClockWise
Circle Counter-ClockWise
Permanent high
Permanent low
Sensor Touch 
Selection [0:1]
Touch
Tap
Double Tap
Colibri Suite Events
MGC3X30 Pins Events mapping
High active
Low active
Toggle
Pulse (100ms)
EIO1,2,3,6,7
EventOutput 1
EventOutput 12
...
AirWheel ClockWise
AirWheel Counter-ClockWise