Datasheet

Datasheet [Page 15]
EMW3166
Humidity
Non condensing, relative humidity
95%
-
ESD 2.6
The Electromagnetic Environment Electrostatic discharge:
Symbol
Item
Conditions
Level
Max
Unit
V
ESD
(HBM)
Electrostatic discharge voltage
(human body model)
TA= +25 °C conforming to
JESD22-A114
2
2000
V
V
ESD
(CDM)
Electrostatic discharge voltage
(charge device model)
TA = +25 °C conforming to
JESD22-C101
II
500
Static Latch-up 2.7
These tests are compliant with EIA/JESD 78A IC latch-up standard.
Table 10 Static Latch-up
Symbol
Item
Conditions
Level
L
U
Static latch-up class
TA= +105 °C conforming to JESD78A
II level A
Other MCU Electrical Parameters 2.8
Please refer to STM32F412xG datasheet for more information.