Data Sheet
Datasheet SHT3x-DIS
www.sensirion.com May 2018- Version 5 4/22
SHT30
SHT31
RH (%RH)
100
±4
±4
±4
±4
±4
±4
±4
±4
90
±3
±3
±3
±3
±3
±3
±3
±3
80
±2
±2
±2
±2
±2
±2
±2
±2
70
±2
±2
±2
±2
±2
±2
±2
±2
60
±2
±2
±2
±3
±2
±2
±2
±2
50
±2
±2
±2
±2
±2
±2
±2
±2
40
±2
±2
±2
±2
±2
±2
±2
±2
30
±2
±2
±2
±2
±2
±2
±2
±2
20
±2
±2
±2
±2
±2
±2
±2
±2
10
±3
±3
±3
±3
±3
±3
±3
±3
0
±4
±4
±4
±4
±4
±4
±4
±4
0
10
20
30
40
50
60
70
80
Temperature (°C)
RH (%RH)
100
±2
±2
±2
±2
±2
±2
±2
±2
±2
90
±2
±2
±2
±2
±2
±2
±2
±2
±2
80
±2
±2
±2
±2
±2
±2
±2
±2
±2
70
±2
±2
±2
±2
±2
±2
±2
±2
±2
60
±2
±2
±2
±2
±2
±2
±2
±2
±2
50
±2
±2
±2
±2
±2
±2
±2
±2
±2
40
±2
±2
±2
±2
±2
±2
±2
±2
±2
30
±2
±2
±2
±2
±2
±2
±2
±2
±2
20
±2
±2
±2
±2
±2
±2
±2
±2
±2
10
±2
±2
±2
±2
±2
±2
±2
±2
±2
0
±2
±2
±2
±2
±2
±2
±2
±2
±2
0
10
20
30
40
50
60
70
80
Temperature (°C)
Figure 5 Typical tolerance of RH over T for SHT30.
Figure 6 Typical tolerance of RH over T for SHT31.
SHT35
RH (%RH)
100
±2
±2
±2
±2
±2
±2
±2
±2
±2
90
±2
±2
±2
±2
±2
±2
±2
±2
±2
80
±2
±2
±2
±2
70
±1.5
±1.5
±1.5
±1.5
±1.5
±1.5
±1.5
±2
±2
60
±1.5
±1.5
±1.5
±1.5
±1.5
±1.5
±1.5
±2
±2
50
±1.5
±1.5
±1.5
±1.5
±1.5
±1.5
±1.5
±2
±2
40
±1.5
±1.5
±1.5
±1.5
±1.5
±1.5
±1.5
±1.5
±2
30
±1.5
±1.5
±1.5
±1.5
±1.5
±1.5
±1.5
±1.5
±2
20
±1.5
±1.5
±1.5
±1.5
±1.5
±1.5
±1.5
±1.5
±2
10
±1.5
±1.5
±1.5
±1.5
±1.5
±1.5
±1.5
±1.5
±2
0
±1.5
±1.5
±1.5
±1.5
±1.5
±1.5
±1.5
±1.5
±2
0
10
20
30
40
50
60
70
80
Temperature (°C)
Figure 7 Typical tolerance of RH over T for SHT35.