Data Sheet

Datasheet SHT3x-DIS
www.sensirion.com May 2018- Version 5 6/22
1.1 Recommended Operating Condition
The sensor shows best performance when operated within recommended normal temperature and humidity range of 5 °C
60 °C and 20 %RH 80 %RH, respectively. Long-term exposure to conditions outside normal range, especially at high
humidity, may temporarily offset the RH signal (e.g. +3%RH after 60h kept at >80%RH). After returning into the normal
temperature and humidity range the sensor will slowly come back to calibration state by itself. Prolonged exposure to
extreme conditions may accelerate ageing. To ensure stable operation of the humidity sensor, the conditions described in
the document “SHTxx Assembly of SMD Packages”, section “Storage and Handling Instructions” regarding exposure to
volatile organic compounds have to be met. Please note as well that this does apply not only to transportation and
manufacturing, but also to operation of the SHT3x-DIS.
2 Specifications
2.1 Electrical Specifications
Parameter
Symbol
Condition
Min.
Typ.
Max.
Units
Comments
Supply voltage
V
DD
2.15
3.3
5.5
V
Power-up/down level
V
POR
1.8
2.10
2.15
V
Slew rate change of the
supply voltage
V
DD,slew
-
-
20
V/ms
Voltage changes on the
VDD line between
V
DD,min
and V
DD
,
max
should be slower than
the maximum slew rate;
faster slew rates may
lead to reset;
Supply current
I
DD
idle state
(single shot mode)
T=25°C
-
0.2
2.0
A
Current when sensor is
not performing a
measurement during
single shot mode
idle state
(single shot mode)
T=125°C
-
-
6.0
idle state
(periodic data
acquisition mode)
-
45
-
A
Current when sensor is
not performing a
measurement during
periodic data acquisition
mode
Measuring
-
600
1500
A
Current consumption
while sensor is
measuring
Average
-
1.7
-
A
Current consumption
(operation with one
measurement per
second at lowest
repeatability, single shot
mode)
Alert Output driving
strength
IOH
1.5x V
DD
mA
See also section 3.5
Heater power
P
Heater
Heater running
3.6
-
33
mW
Depending on the
supply voltage
Table 3 Electrical specifications, typical values are valid for T=25°C, min. & max. values for T=-40°C … 125°C