3 Specifications
General Parameters
Product Model
SenseCAP ORCH S4
Power Supply
3.6 ~ 16V
Protocol
MODBUS-RTU RS485/ MODBUS-ASCII RS485/ SDI-12 (v1.4)
IP Rating
IP66 (water-proof box);IPX5 (solar radiation shield)
Operating Temperature
-40 ℃ ~ +65 ℃
Operating Humidity
0 ~ 100 %RH (non-condensing)
Measurement Parameters
Range
Accuracy
Resolution
Drift
Air Temperature
-40~+85 ℃
±0.2 ℃
0.1 ℃
<0.3
℃/year
Air Humidity
0~100 %RH
±1.5 %RH
1 %RH
<0.25%
RH/year
Barometric Pressure
300~1100 hPa
Relative Accuracy (700~900
hPa/ 25~40℃): ±0.12 hPa
Absolute Accuracy (300~1100
hPa/ -20~0℃): ±1.7 hPa
Absolute Accuracy (300~1100
hPa/ 0~65 ℃): ±1.0 hPa
1 Pa
±1.0 hPa/year
Light Intensity
0~188000 Lux
± 5%
0.045 Lux
—
Current Consumption
Power Supply (V)
16
12
5
3.6
RS-485
working current (mA)
3.60
4.70
11.00
14.50
SDI-12
working current (mA)
3.04
3.98
8.85
11.80
Sleep current (μA)
40.00
45.30
77.60
2.24 (mA)
Program Parameters
Parameter
Min
Typical
Max
Unit
RS-485
Warm-up Time
[1]
300
300
[2]
1000
millisecond
Scan Interval
[3]
—
1000
—
millisecond
Poll Rate
[4]
—
1
—
Hz
Response Time
[5]
1
—
4
millisecond
SDI-12
Warm-up Time
[6]
—
15
—
millisecond
Scan Interval
[7]
350
350
[8]
1200
millisecond
[1] The time from when the sensor is powered on to when the data is read. Note the parameter when the
sensor is powered on.
[2] When the light intensity is greater than 150 Lux, the warm-up time of the value (@typical 300ms) can
ensure 100% reading of the correct data. When the light intensity is less than 150 Lux, the warm-up time
of the value (@max 1000ms) can ensure 100% reading of the correct data.