User manual

Working with the SEH UTN Manager
myUTN User Manual 70
Creating a UTN Action: Automated Device Connections and
Program Starts without the SEH UTN Manager Interface
You can create UTN actions. UTN Actions are small programs used
for the automatic activation and deactivation of device connections.
UTN Actions can also automate the starting and closing of an
application in combination with a device connection.
The process defined in the UTN action will run automatically after
the execution of the file. Since the 'SEH UTN Service' is active in the
background, the user is not required to start the SEH UTN Manager
interface. I.e., UTN Actions can be used with the complete and
minimal version.
A wizard within the SEH UTN Manager will guide you through the
process of creating a UTN Action. The following UTN Actions can be
created:
UTN Actions which activate and deactivate the device
The wizard will automatically create one UTN Action for the activation and one UTN Action for
the deactivation of the device. Both UTN Actions will be saved to the desktop.
UTN Action which starts an application and activates the
device
After the selection of an application by the user, the wizard will automatically create an action
which starts an application and activates the device. Additionally, you can specify a device
deactivation after the closing of the application.
Custom UTN Action (Experts only)
With the help of the wizard, a custom UTN Action can be created. You can create:
- UTN Actions which activate and deactivate the device. You can define additional options.
- A script for the start of the application and activation of the device. Additionally, you can
specify a delay for the start of the application, the deactivation of the device after the closing of
the application and additional options. The script will be created automatically and can then be
edited. Finally, the complete UTN Action will be created automatically by the SEH UTN Manager
and saved by the user.
Requirements
; The USB device is shown in the selection list; see: Ö63.
Proceed as follows:
1. Start the SEH UTN Manager.
2. Mark a USB device in the selection list.
3. Select Device – Create UTN Action from the menu bar.
The dialog Create UTN Action will be started.