Product manual
3-6
Installing the Drive
650 Series AC Drive
P3
72mm
26mm
54m
m
7mm
mm
15.5
±
1
0
3.5
±
0.5
0
mm
32
±
2
0
mm
mm 5.5
±
0.5
mm
25
±
0.5
mm
58
±
0.5
Template
Cut-out
21
1
P3
4
3
Optional Equipment
Two types of keypad are available:
Eurotherm Part No. 6511/DISP/... not suitable for remote-mounting
Eurotherm Part No. 6511/DISPR/...suitable for remote-mounting on drives with an RS232 port
Both types can be fitted to the front of any 650 drive. However, not all drives are fitted with the
RS232 (P3) port required for remote-mounting the Remote Keypad. Refer to Chapter 9:
"Technical Specifications" - Understanding the Product Code.
Fitting the Remote Keypad
You can remote-mount the drive-mounted keypad using:
•
a Remote Keypad (identified by the RS232
connector on the back
•
the RS232 (P3) port located under the
terminal cover
A standard P3 lead, Eurotherm Part Number
CM057375U300, is used to connect the keypad to
the drive.
Two self-tapping screws are provided with the
keypad. Remove the protective film from the
gasket. An enclosure rating of IP54 is achieved
for the remote keypad when correctly mounted.
Assembly Procedure
Cut-out Dimensions
The drawing below can be photocopied actual size (100%) and used as a template.