Product manual
6-3
Programming Your Application
650 Series AC Drive
Display
DisplayDisplay
Display Parameter
ParameterParameter
Parameter Description
DescriptionDescription
Description Range
RangeRange
Range Default
DefaultDefault
Default
PRESET 4 A user-adjustable speed preset -100.00 to 100.00 -10.00
PRESET 5 A user-adjustable speed preset -100.00 to 100.00 -20.00
PRESET 6 A user-adjustable speed preset -100.00 to 100.00 -50.00
PRESET 7 A user-adjustable speed preset -100.00 to 100.00 -100.00
Parameters
P
401 to
P
404 are visible in the PAR menu when Application 4 is selected in parameter
P
1
R/L RAMP TIME The time taken to ramp the Raise/Lower output
from 0.00% to 100.00% of its value
0.0 to 600.0s 10.0s
R/L MAX VALUE The maximum value for the ramp output -100.0 to 100.0% 100.0%
R/L MIN VALUE The minimum value for the ramp output -100.0 to 100.0% 0.0%
R/L RESET VALUE The value the output is set to when Reset is TRUE,
when DIN4 (terminal 10) is 24V in Application 4
-100.00 to 100.00% 0.00%
Parameters
P
501 and
P
502 are visible in the PAR menu when Application 5 is selected in parameter
P
1
PI P GAIN The PI proportional gain 0.00 to 100.00 1.00
PI I GAIN The PI integral gain 0.00 to 100.00 0.00
PID D GAIN
F
The PID derivative gain 0.00 to 100.00 0.00
PID D FILTER TC
F
In order to help attenuate high frequency noise on
the derivative term, a first order lag has been
provided. This parameter determines the filter time
constant.
0.05 to 10.00s 0.05s
PID FEEDBACK
GAIN
F
A multiplier applied to the feedback signal of the
PID
-10.00 to 10.00 1.00
PID LIMIT
F
Determines the maximum positive and negative
excusrion (Limit) of the PID output
0.00 to 300.00% 300.00%
SET::IN Menu
SET::IN MenuSET::IN Menu
SET::IN Menu
DIN 1 INVERT Inverts the value of the signal, TRUE or FALSE. 0= NOT INVERTED
1= INVERTED
0
DIN 2 INVERT As
S
IP01 As
S
IP01 0
DIN 3 INVERT As
S
IP01 As
S
IP01 0
DIN 4 INVERT As
S
IP01 As
S
IP01 0
AIN 1 SCALE -150.0 to 150.0% 100.0%
AIN 1 OFFSET -100.0 to 100.0% 0.00%
AIN 1 TYPE
VALUE
+
SCALE
OFFSET
X
INPUT
TYPE
UNPROCESSED
0 to 100% of selected TYPE
0= 0-10V
1= 0-5V
0
AIN 2 SCALE -150.0 to 150.0% 0.00%
AIN 2 OFFSET -100.0 to 100.0% 100.0%
AIN 2 TYPE
VALUE
+
SCALE
OFFSET
X
INPUT
TYPE
UNPROCESSED
0 to 100% of selected TYPE
0= 0-10V
1= 0-5V
2= 0-20mA
3= 4-20mA
3
DIN 1 VALUE
F
The TRUE or FALSE input (after any inversion) 0=FALSE
1=TRUE
0
DIN 2 VALUE
F
The TRUE or FALSE input (after any inversion) 0=FALSE
1=TRUE
0
DIN 3 VALUE
F
The TRUE or FALSE input (after any inversion) 0=FALSE
1=TRUE
0