Product manual

Programming Your Application
6-4
650 Series AC Drive
Display
DisplayDisplay
Display Parameter
ParameterParameter
Parameter Description
DescriptionDescription
Description Range
RangeRange
Range Default
DefaultDefault
Default
DIN 4 VALUE
F
The TRUE or FALSE input (after any inversion) 0=FALSE
1=TRUE
0
AIN 1 VALUE
F
The input reading with scaling and offset applied
.xx%
0.00%
AIN 2 VALUE
F
The input reading with scaling and offset applied
.xx%
0.00%
SET::OUT Menu
SET::OUT MenuSET::OUT Menu
SET::OUT Menu
AOUT 1 SOURCE
ANALOG OUTPUT
0 NONE
1 DEMAND %
2 CURRENT %
3 PI ERROR %
4 RAISE/LOWER %
SCALE
OFFSET
ABSOLUTE
0-10V
OUTPUT
0= NONE
1= DEMAND
2= CURRENT
3= PI ERROR
4= RAISE/LOWER
OUTPUT
1
AOUT 1 SCALE -300.0 to 300.0 100.0%
AOUT 1 OFFSET -300.0 to 300.0% 0.00%
AOUT 1
ABSOLUTE
+
SCALE
OFFSET
X
VALUE
ABS
X
OUTPUT
100%
0%
CLAMP
0= NOT ABSOLUTE
1= ABSOLUTE
1
DOUT 2 SOURCE
Refer to
Configuring
Terminal 10
(Digital
Input/Output),
page 6-6.
DIN4 / DOUT2
0 NONE
1 HEALTH
2 TRIPPED
3 RUNNING
4 AT ZERO
5 AT SPEED
INVERT (output)
6 AT LOAD
0= NONE
1= HEALTH
2= TRIPPED
3= RUNNING
4= AT ZERO
5= AT SPEED
6= AT LOAD
0
DOUT 2 INVERT (OUTPUT) As
S
IP01. Set to 0 for applications 1 &
5.
As
S
IP01 0
RELAY SOURCE NONE : Relay is open
Relay is closed when:
HEALTH : the Run signal is not present, or no trip
is active
TRIPPED : a trip is present
RUNNING : the motor is running
AT ZERO : the output frequency is below 1% of
MAX SPEED (
P
2)
AT SPEED : the output frequency is within 1% MAX
SPEED (
P
2)
AT LOAD : the magnitude of the output torque is
greater than or equal to the torque level set in
ST
42
RELAY
0 NONE
1 HEALTH
2 TRIPPED
3 RUNNING
4 AT ZERO
5 AT SPEED
INVERT (output)
6 AT LOAD
As
S
OP21 1
RELAY INVERT As
S
IP01 As
S
IP01 0