Product manual

Technical Specifications
9-4
650 Series AC Drive
Electrical Ratings
Motor power, output current and input current must not be exceeded under steady state
operating conditions.
Maximum Motor dv/dt = 10,000V/ยตs. This can be reduced by adding a motor choke in series
with the motor. Contact Eurotherm Drives for recommended choke details.
Local wiring regulations always take precedence. Select cable rated for the drive.
The supply must be protected with a fuse (or Type B RCD) rated to the supply cable.
FRAME 1 : 1-Phase (IT/TN), 230V
Input Current @ 5kA
Input Current @ 5kAInput Current @ 5kA
Input Current @ 5kADrive
DriveDrive
Drive
Power
PowerPower
Power
(kW/hp)
(kW/hp)(kW/hp)
(kW/hp)
Surge Current
Surge CurrentSurge Current
Surge Current
peak/rms for 10ms (A)
peak/rms for 10ms (A)peak/rms for 10ms (A)
peak/rms for 10ms (A)
(A)
(A)(A)
(A)
Output Current @ 40
Output Current @ 40Output Current @ 40
Output Current @ 40
o
oo
o
C
CC
C
(A) ac
(A) ac(A) ac
(A) ac
Maximum Power
Maximum PowerMaximum Power
Maximum Power
Loss
LossLoss
Loss
(W)
(W)(W)
(W)
0.25/0.3 19/12 4.2 1.5 26
0.37/0.5 19/12 6.2 2.2 32
0.55/0.75 20/14 7.9 3.0 41
0.75/1.0 22/15 10.5 4.0 52
FRAME 2 : 1-Phase (IT/TN), 230V
Input Current @ 5kA
Input Current @ 5kAInput Current @ 5kA
Input Current @ 5kA
Drive
DriveDrive
Drive
Power
PowerPower
Power
(kW/hp)
(kW/hp)(kW/hp)
(kW/hp)
Surge Current
Surge CurrentSurge Current
Surge Current
peak/rms for 10ms (A)
peak/rms for 10ms (A)peak/rms for 10ms (A)
peak/rms for 10ms (A)
(A)
(A)(A)
(A)
Output Current @ 40
Output Current @ 40Output Current @ 40
Output Current @ 40
o
oo
o
C
CC
C
(A) ac
(A) ac(A) ac
(A) ac
Maximum Power
Maximum PowerMaximum Power
Maximum Power
Loss
LossLoss
Loss
(W)
(W)(W)
(W)
1.1/1.5 24/17 13.8 5.5 65
1.5/2.0 25/18 16.0 7.0 82
FRAME 2 : 3-Phase (IT/TN), 400V
Drive
DriveDrive
Drive
Power
PowerPower
Power
(kW/hp)
(kW/hp)(kW/hp)
(kW/hp)
Input Current @ 10kA
Input Current @ 10kAInput Current @ 10kA
Input Current @ 10kA
(A)
(A)(A)
(A)
Output Current @ 40
Output Current @ 40Output Current @ 40
Output Current @ 40
o
oo
o
C
CC
C
(A) ac
(A) ac(A) ac
(A) ac
Maximum Power
Maximum PowerMaximum Power
Maximum Power
Loss
LossLoss
Loss
(W)
(W)(W)
(W)
0.37/0.5 2.5 1.5 26
0.55/0.75 3.3 2.0 32
0.75/1.0 4.1 2.5 40
1.1/1.5 5.9 3.5 55
1.5/2.0 7.5 4.5 61
2.2/3.0 9.4 5.5 70
FRAME 3 : 3-Phase (IT/TN), 200V
Drive
DriveDrive
Drive
Power
PowerPower
Power
(kW/hp)
(kW/hp)(kW/hp)
(kW/hp)
Input Current @ 10kA
Input Current @ 10kAInput Current @ 10kA
Input Current @ 10kA
(A)
(A)(A)
(A)
Output Current @ 40
Output Current @ 40Output Current @ 40
Output Current @ 40
o
oo
o
C
CC
C
(A) ac
(A) ac(A) ac
(A) ac
Maximum Power
Maximum PowerMaximum Power
Maximum Power
Loss
LossLoss
Loss
(W)
(W)(W)
(W)
2.2/3.0 14.3 9.6 82
3.0/4 18.1 12.3 108
4.0/5 23.1 16.4 147
FRAME 3 : 3-Phase (IT/TN), 400V
Drive
DriveDrive
Drive
Power
PowerPower
Power
(kW/hp)
(kW/hp)(kW/hp)
(kW/hp)
Input Current @ 10kA
Input Current @ 10kAInput Current @ 10kA
Input Current @ 10kA
(A)
(A)(A)
(A)
Output Current @ 40
Output Current @ 40Output Current @ 40
Output Current @ 40
o
oo
o
C
CC
C
(A) ac
(A) ac(A) ac
(A) ac
Maximum Power
Maximum PowerMaximum Power
Maximum Power
Loss
LossLoss
Loss
(W)
(W)(W)
(W)
3.0/4 11.1 6.8 80
4.0/5 13.9 9.0 100
5.5/7.5 18.0 12.0 136
7.5/10 23.6 16.0 180