Product manual
Applications
12-4
650 Series AC Drive
Application 3 Preset Speeds
Preset Speeds
IDEAL FOR APPLICATIONS REQUIRING
MULTIPLE DISCRETE SPEED LEVELS
P1 APPLICATION = 3
p1 Application
p2 Max speed
p3 Min speed
p4 Accel time
p5 Decel time
p6 Motor rated current
p7 Base frequency
p8 Jog setpoint
p9 Stop mode
p11 V/F shape
p12 HVAC ratings
p13 Fixed boost, (VF only)
p99 Password
STANDARD PARAMETERS
Italic text indicates Default
(SCALABLE)
Application 3:
Speeds
Preset
1 Setup
2 Clean
3 Operate 1
4 Operate 2
Frequency Hz
Speed Setpt %
DC Link Volts V
Motor Current A
DIAGNOSTICS
1
2
3
4
5
6
7
8
9
10
0V
AIN1
AIN2
+10V REF
AOUT1
+24V
DIN1
DIN2
DIN3
DIN4/DOUT2
AUTO REF
MAN.
REF
PRESET IN
START/STOP
SPEED DEMAND
SEQUENCING LOGIC
RAMP
CURRENT LIMIT
P6 I NOMINAL
P4 ACCEL TIME
P5 DECEL TIME
PWM CONTROL
V/F SHAPING
CT
VT
V
F
V
F
I FDBK
V
F
SPEED DEMAND
FWD/REV
MIN/MAX SPEED
PRESET IN
PRESET IN
P9 STOP MODE
P9 STOP MODE
DIN4/
DIN3 DIN2 PRESET
0V 0V 0V
0V 0V 24V
0V 24V 0V
0V 24V 24V
24V 0V 0V
24V 0V 24V
24V 24V 0V
24V 24V 24V
0
1
2
3
4
5
6
7
RL1A
RL1B
User
Relay
R
0 NONE
1 HEALTH
2 TRIPPED
3 RUNNING
4 AT ZERO
5 AT SPEED
OP31 RELAY
0 = CONSTANT TORQUE
1 = VARIABLE TORQUE
P7
BASE FREQ
P13 V BOOST
P11 V/F SHAPE
50/60Hz base frequency
P2 MAX SPEED
P3 MIN SPEED
P301 PRESET 0
P302 PRESET 1
P303 PRESET 2
P307 PRESET 6
P306 PRESET 5
P305 PRESET 4
P304 PRESET 3
P308 PRESET 7
Speed
Meter
(at default
1 setting)
DOUT2