5. Measurement
1. Measuring ambient light
In this measurement mode, we have the choice of shutter priority mode, aperture priority mode and
EV mode. Hold down the Mode set button !0 and turn the Set/change dial t to select ambient
measurement mode
.
1-1 Shutter Speed Priority mode
1. Hold down the Mode set button !0 and turn the
Set/change dial t to select shutter Speed Priority
mode.
2. Turn the Set/change dial to set the desired shutter
speed.
3. Press the Measuring button !5 to make a
measurement. Release the Measuring button to
complete the measurement. The measured value
(aperture value) at that time will be displayed.
While pressing the Measuring button, the meter
measures continuously until it is released.
Reference:
It is possible to switch between 1, 1/2 and 1/3 shutter speed steps by setting DIP switch
4.
You can set shutter speeds from 30 minutes to 1/8000 seconds. After 1/8000 the shutter
speeds of 1/200 and 1/400 can be set.
After measurement, the F stop value corresponding to the shutter speed is displayed
when the shutter speed is changed.
The measured F value is displayed in 1/2 stops in the liquid crystal dot display (1/3
stops are not displayed). 608 Cine displays values in 1/3 stops only.
E.u (Exposure under) or E.o (Exposure over) appears when the combination of shutter
speed and aperture is not possible for the measured light level. Changing the shutter
speed and or aperture with the Set/change dial will allow you to find a combination that
is possible. The 'E.o' or 'E.u' mark may be displayed at the maximum and minimum F
values, F45 and F0.5, respectively, with the 608 Cine.
If the E.u or E.o readout blinks, this indicates that the light level is beyond the
measurement range of the light meter.
Measured f stop
value
1/10
f stop
Set
shutter speed
Measured f stop
POWER
ISO 1
MODE
ISO 2
AVE./EV
MEMORY