User's Manual

ENGLISH
-21-
2-3 Cord multiple flash (cumulative) mode
These measurements are used when the light generated by the flash is inadequate for proper
exposure. The repeated flash pops can be accumulated until the desired aperture is displayed.
The cumulative number is infinite. Only one digit is displayed if the cumulative number is ten or
more.
1. Slide DIP switch 2 to MULTI (see page 9) to the
ON position.
Hold down the Mode set button !0 and turn the
Set/change dial t to select cord multiple flash
(cumulative) mode (MLT will display on the LCD).
2. Turn the Set/change dial t to set shutter speed. When setting shutter speed, first check
the settings to confirm that they correspond to the settings available on the camera.
3. Connect the Flash synchro cord to the meter's
synchro terminal i.
4. Press the Measuring button !5 to trigger a flash. The measured f stop value at that time will
be displayed. Each time this is repeated, the accumulated f stop value and the number of
cumulative flashes is displayed.
5. To release the cumulative mode, switch to another mode by turning the Set/change dial
while pressing the mode set button.
5. Measurement
f stop
Measured f stop
1/10 f stop
Number of
cumulative flashes
Set
shutter speed
The ratio of flash
element to the total
amount of light
MODE