q Operating instructions SAFETY PRECAUTIONS This manual uses the following safety labels for that you must follow. /b WARNING ACAUTION A /b AWARNING and ACAUTION Indicates hazards or unsafe practices that can result in severe personal injurry or death. Indicates hazards or unsafe practices that can r esult in personal injury or damage to your L-308Bll exposure meter. (CAUTIONI Indicates an operation note or limitation you must use. Please read the notes to avoid an incorrect L-308BII operation.
CONTENTS SAFETY PRECAUTIONS .......................................................................................... i CONTENTS .................................................................................................................... ii 1. Parts Designations ...................................................................................... 1 2. 2 2 Display ................................................................................................................... 2.
1.
2. Display 2.1 LCD panel 0 Mode selection 0 m IS0 film speed display. See Page 6. Ambient light measurement Press the IS0 button, and m is displayed. Flash measurement without cord Flash measurement with cord mode symbols are switched in the following sequence: 8 Aperture/EV/Battery/Others “b.c” Battery capacity z:‘$ See Page 5. Aperture value (Indicated by a number and dots $“; ) Exposure value (Indicated by a number and dots $‘$ ) See Page 7. E.u Under exposure E.
3. Mode Selection Your L-308Bll can measure both incident and reflected light in both ambient light and flash light (electronic flash or flash bulb) modes. You can switch the modes as follows: [Ligh&y.eng [Ligh$xec#ng [Measured light] [Mode/display method] see Page 7. 3.1 Switching between incident light metering and reflected light metering Slide the lumisphere and stop it at the clicking position of “a” or “b” (See Fig.1 and 2). 5 Lumisphere b Fig. 1 Incident light metering Caution: 3.2 Fig.
4, Light-receiving Method 4.1 Incident light metering Hold L-308BII close to the subject, point the lumisphere towards the camera, and measure the incident light intensity, (Fig. 8) ;Q,, //// II Fig. 8 Caution: Do not fit the Lumidisc next to the Lumisphere when you take incident light metering. Otherwise, the Lumidisc will affect the exposure in proper reading. 4.
5. Preparation for Measurement 5.1 Inserting the battery Use a 1.5-volt, type-AA battery. Use a manganese dry cell (R6P) or an alkaline one (LR6). Never use any of other types. 0 To remove the battery case cover simply slide it in the direction of the arrow. 0 Insert the battery in the battery case aligning the polarities as indicated on the inside of the case. (Fig. 10) 8 Slide the battery case cover along the unit to close it. Check that the cover is securely closed. 5.
0 If you press the mode selector in the ambient light measurement mode while holding down the IS0 button, the display is toggled between EV and F values (Fig. 12 and 13). If it is toggled after measurement, the measurement data is automatically recalculated and redisplayed. NOTE Fig. 12 5.5 Fig. 13 Setting up film speed (ISO) 0 Press the IS0 button, and a film speed value is displayed (Fig. 14). @ Set up the film speed by pressing the Up or Down button while holding down the IS0 button.
6. Ambient Light Measurement 6.1 Mode Selection 0 Press the mode selector to enter the ambient light measurement mode. 0 Set up the film and shutter speeds. @ Press the measuring button, and the aperture value is displayed (Fig. 17). Fia. 17 0 Fig. 17 shows the shutter speed 1/125, and aperture F2.0+3/10 measured. l In the ambient light measurement mode, light measurement is continuously conducted while the measuring button is kept depressed.
7.. Flash Measurement with cord 7.1 Setting up of the flash measurement with cord and making measurement in this mode 0 Press the mode selector to enter this mode (Fig. 21). @I Set up the film and shutter speeds. Fig. 21 Caution: l l Set up the shutter speed which has been already set up on your camera. If you measure the flash bulb light, make sure that the shutter speed set is within the synchronizing range. 0 Connect the synchro cord to the L-308Bll’s synchro terminal (Fig. 22). B c--- J \F Fig.
8. Flash Light Wireless Measurement (Measurement without using the syrchro cord) 8.1 Flash light wireless measurement (1> Press the mode selector to enter this mode (Fig. 24). @ Set up the film and shutter speeds. Fig. 24 Caution: Set up the shutter speed which has been already set up on your camea. 0 Press the measuring button. After releasing it, mark blinks showing that your L-308BII is in a stand-by mode (Fig.25); this holds for about 90 seconds.
ow to use the Lumidisc How to measure light contrast 9.1 @) Fit the Lumidisc on the light receiving part. See page 3 ‘3.2 How to fit the Lumidisc’. @ Select the light mode you are going to use with the mode selector. @ Hold the L-308BII close to the subject and point the Lumidisc toward the main light source (turn off the auxiliary light source). Take reading. @I Keep holding the L-308BII close to the subject and point the Lumidisc toward the auxiliary light source (turn off the main light source).
10. Specifications Digital exposure meter for ambient and flash metering Incident and reflected light metering system l Incident light: Lumisphere, Lumidisc l Reflected light: Lens (light receiving angle of 40°) Light receiving element l Silicon photo diode 0 Ambient light: Shutter speed-priority metering Metering systems l Flash light: With synchro cord Without synchro cord l Ambient light: EVO to EV19.9 (at 0.1 EV step) Measuring range F1.4 to F90 + 0.9 stop (at 0.1 AV step) (IS0 100) * Flash: kO.
11. Instructions and Maintenance Notes Caution: l To avoid damaging your L-308611, never drop it or subject it to impact. 0 Avoid keeping your L-308Bll in places of high temperature or humidity. l Avoid excessive temperature changes, otherwise condensation will occur, resulting in malfunction l Remove the battery if your L-308Bll is not to be used for a long time. MAINTENANCE NOTES l l Keep the surfaces of the lumisphere, lens and Lumidisc clean and free from dust, foreign particles and scratches.
Quick Guide to the Sekonic L-308 LUMISPHERE ON/OFF BATTERY CHECK 1/10 STOP INCREMENTS MEASURE MODE FLASH FLASH W/CORD DAYLIGHT DAYLIGHT UP DOWN ISO · DEPRESS WHILE PUSHING UP OR DOWN SWITCH · IN DAYLIGHT MODE , TO TOGGLE BETWEEN F-STOP AND EV, TAKE READING, HOLD DOWN ISO, TOGGLE BETWEEN BY USING MODE BUTTON FLASH CORD SOCKET WHEN CORD IS ATTACHED PUSH MEASURE BUTTON TO TRIGGER FLASH AND MEASURE LIGHT
Basic Operation - Sekonic L-308 On/Off/Battery Check Press Power button. To check battery power hold down button.
FLASHMATE Operating Manual
■ SAFETY PRECAUTIONS This manual uses the following safety labels for that you must follow. WARNING and CAUTION WARNING Indicates hazards or unsafe practices that can result in severe personal injury or death. CAUTION Indicates hazards or unsafe practices that can result in the personal injury or damage to your L-308S exposure meter. NOTE: Indicates a caution or limitation that accompanies operation. Please read the note to avoid incorrect operation.
Table of Contents Safety Precautions Table of Contents 1. Parts Designation .......................................................................... 1 2. Explanation of the Liquid Crystal Display (LCD) .......................... 2 3. Before Using .................................................................................. 3 1. Attach the strap .......................................................................... 3 2. Inserting the battery ........................................................
1.
2. Explanation of the Liquid Crystal Display (LCD) explanation purposes, the display illustrated here shows icons and * For readouts simultaneously. Actual display will never appear like this. q Measuring Mode icons w e r t y Ambient (See page 10) Auto Reset Cordless Flash (See page 16) Cord Flash (See page 14) ISO Display (See page 5) Displays ISO Film setting. Aperture/EV display Appears when aperture value is displayed. Appears when using EV mode. (See page 11) 0.
3. Before Using 1. Attach the strap 1) Attach the Strap !5 by passing the small end loop through the strap eyelet !2 and passing the other end of strap through it. WARNING ● Please place in a location where an infant cannot reach and accidentally get the strap wrapped around his or her neck. There is danger of strangulation. 2. Inserting the battery 1) Requires type-AA 1.5-volt manganese dry cell battery (R6P) or type-AA 1.5-volt alkali dry cell battery (LR6) or type-AA 1.
3. Before Using 3. Checking battery capacity When the Power button q is ON, the battery power indicator on the LCD t is displayed. (Displayed) Battery power level is good. (Displayed) Battery power level is low. Have a spare battery ready. (Blinking) Replace battery immediately. REFERENCE: • If the liquid crystal display extinguishes immediately after the display appears when power is first applied, that is an indication that the battery is dead. Please promptly replace the battery.
3. Before Using 5. Auto Power OFF function 1) To conserve battery power, the meter will turn OFF about four minutes after last use. 2) Whether the Auto Power OFF function turns the power OFF or the Power button q is pressed, the settings and measured values remain stored in memory. When the Power button is pressed again the last settings are displayed. REFERENCE: • The power shuts OFF automatically after one minute when the power button is pressed and held. 6.
4. Basic Operation 1. Incident or reflected light measuring 1) To set for either incident or reflected light operation, slide the Lumisphere w mounting until it clicks. Incident light mode NOTE: Reflected light mode Setting operation ● Always use the Lumisphere mounting for setting. Hand operation of the Lumisphere may cause damage. ● The Lumisphere is an important light receiving unit. Please handle with care and try not to mark or soil. Wipe Lumisphere with a dry soft cloth if it becomes dirty.
4. Basic Operation 2) Interchangeably switch between EV mode and Shutter Speed Priority mode by pressing the Mode button e while holding down the ISO button i in Ambient mode. Measurement value also will be automatically calculated when a switch is made after measuring. MODE ISO REFERENCE: • Ambient light refers to continuous light like natural light (sunlight), tungsten lamps or fluorescent lamps. • Flash light is a brief, intense burst of light made by such as electronic flash units or flash bulbs.
4. Basic Operation 3. When set for incident light Incident light measuring is the measurement method that employs either the Lumisphere or Lumidisc functions. Measure with the lumisphere ai med in the camera direction at the position of the subject. 1) Using Lumisphere to Measure Lumisphere is used to measure people and buildings and other such solid objects.
4. Basic Operation 4. When set for reflected light Point the lens of the exposure meter toward the part of the subject to be measured from the camera position or from the camera direction and then measure. 1) This method is used to measure the brightness (luminance) of light reflected from the subject and is useful for metering subjects that cannot be approached or light-generating subjects (neon signs, etc.), highly reflective surfaces or translucent subjects (stained glass, etc.).
5. Measurement 1. Measuring Ambient Light In this measurement mode, we have the choice of shutter priority mode and EV mode. Press the Mode button e to select the Ambient mode. MODE 1-1 Shutter Speed Priority mode 1) Press the Mode button to select the Shutter Speed Priority mode. 2) Press the Up button y or Down button u to set the desired shutter speed. 3) Press the measuring button r to make 1/10 step measurement a measurement. Release the measuring value (f stop) button to complete measurement.
5. Measurement ✩ When the display range is exceeded, and E.o appears, press the Up button y to change the shutter speed to the high-speed side and thus enable an appropriate corresponding aperture value to be displayed. ✩ When the display range is exceeded, and E.u appears, press the Down button u to alter the shutter speed to the slow-speed side and thus enable an appropriate corresponding aperture value to be displayed. NOTE: • When brightness (or darkness) exceeds the measuring range of the L-308S, E.
5. Measurement 2) Press measuring button r to make a measurement. Release the measuring button to complete the measurement. The measured value (EV value) at that time will be displayed. While pressing the measuring button, the meter measures continuously until it is released. REFERENCE: Measurement value (EV) • EV (exposure value) is the reading that logarithmically expresses the constant quantity of light combined from the shutter speed and aperture value.
5. Measurement 1-3 Cinematography 1) Press Mode button e to select Shutter Speed Priority mode. 2) Press the Up button y or Down button u to select the cine speed for the camera that will be used. MODE The following cine speeds will be displayed after 1/6000 and 1/8000: 8, 12, 16, 18, 24, 25, 30, 32, 60 and 128 fs. The shutter angle that these speeds are based on is 180 degrees.
5. Measurement 2. Measuring Flash Light This measuring method comprises the cord and cordless flash modes. Measure the flash light to display shutter speed and aperture value (total amount of light combining ambient light and flash light) on the LCD. 2-1 Cord Flash mode This measuring methad is used to make sure synchronization with flash units, or to measure flash bulb by connecting Synchro cord. 1) Connect the flash synchro cord to the flash synchro terminal o on the exposure meter.
5. Measurement NOTE: ● There is a danger of electric shock if the meter is handled with wet hands, during rain, in areas splashed by water or where there is a lot of moisture, if you use cord flash mode. ● The electronic flash unit may trigger when you connect the synchro cord or operate the Power button. ● For flash unit with an extremely low trigger voltage, the flash may not fire. In this case, make measurements in auto reset cordless flash mode.
5. Measurement ✩ When the display range is exceeded (E.u), press the Down button u to change the shutter speed to the low-speed side, or raise the quantity of flash light and measure again to display a measurement value (aperture value). ✩ When brightness (or darkness) exceeds the measuring range of the L-308S, E.o (or E.u) will blink to indicate that measuring is not possible. In such cases please adjust the quantity of flash light and measure again.
5. Measurement 4) If the 90 second period is exceeded and the blinking mark stops, press the Measuring button again to return to ready to measure. 5) When the light from the flash is received, the measured value (f stop) is displayed. Even after measurement, the mode mark continues to blink and the meter is in ready state and a new measurement can be made.
6. Advanced Functions 1. Measuring Light Contrast This method is used to check studio lighting or lighting unevenness. 1) Mount the Lumidisc accessory (see page 8). 2) Turn ON just the main light source. Point the Lumidisc at the main light source from the subject position and then measure. 3) Next turn ON just the secondary light source. In this state now point the Lumidisc at the secondary light source and measure. EV Difference of Measuring Value Contrast Ratio 1 2:1 1.
6. Advanced Functions 2. How to use an incident illuminance (LUX or FC) meter 1) 2) 3) 4) Mount the Lumidisc accessory (see page 8). Set EV mode and ISO 100. Measure with the area to be measured parallel to the Lumidisc. Determine the illuminance (lux) from the calculation table using the measured EV.
6. Advanced Functions 3. Custom setting function POWER To match your camera, you can set the setting value and display value to full, 1/2 or 1/3 stop. MODE 1) To enter custom setting mode, hold down the Mode button e and turn ON the power button q. 2) Once custom setting mode is entered, the ‘CS’ for custom setting will be displayed in the ISO display area, and the setting number will be displayed in the aperture value display area.
7. Accessories ● Synchro cord (Sold Separately) This is a five-meter long cord with three plugs. An exposure meter, a camera, and a flash can all be connected at the same time. This is convenient when measurements are made, because it is not necessary to plug and unplug the synchro cord. Also one side of synchro cord has a look feature to make sure connection with the meter.
8.
9. Safty Guide and Maintenance NOTE: ● To avoid damage to meter, never drop or subject it to shock. ● Avoid storping meter in places with high temperature and/or humidity. ● Be careful excessive temperature changes that could cause humidity and internal condensation, resulting in malfunction. ● If the temperature of the meter drops to -10°C or beyond, response of the LCD becomes extremely slow and displays are difficult to read.
7-24-14, OIZUMI-GAKUEN-CHO, NERIMA-KU, TOKYO 178-8686, JAPAN TEL: +81(0)3-3978-2335 FAX: +81(0)3-3978-5229 http://www.sekonic.co.