5-3-3. Using the Power Control Settings
Select Radio Triggering Mode and ControlTL
®
under
Radio System Preference within Custom Setting to use
the Power Control Function.
* Be sure to set the T (shutter speed) and ISO
sensitivity values desired in the Measuring screen
before adjusting power levels and metering the
controlled ash intensity.
1. Touch the Measuring mode icon to open the
Measuring Mode Selection screen, then touch
the
icon to activate Radio Triggering Mode
and return the screen view to the Measuring
screen (See P25 for details.)
2. Touch the Power Control icon (
)
1
to display
the Power Control screen.
3. Adjust ash intensity for ControlTL
®
.
*
Please set the ControlTL
®
and Standard
channels in advance. (See P39 for details.)
a. Touch the ControlTL
®
Zone buttons at the
bottom to select A, B, C
6
.
b. The Power Bar
4
and values
3
will
be activated as each Zone (A,B,C) is
selected. The current level appears at the
top of the bar.
c. Touch the +/- icons or slide nger up/
down on the slider to set values.
d. Repeat a to c above to select other zones and
set values.
e. Pressing the Measuring button on the side
of meter will display the F value (f-stop) for
each zone
5
as measured value for the
set T (shutter speed) and ISO sensitivity
value.
f. The total F value (f-stop) for selected
zones will be displayed in item
8
.
g. Touch the
7
modeling lamp icon to turn
ON or OFF studio ash modeling lamps.
h. Touch the Radio Triggering Mode icon
9
to return to the Measuring screen.
4. In this screen, Zones of Standard CH can be
turned ON or OFF
2
for the Channel from 17 to
32. If the standard CH is set to 1 to 16, receivers
are set to ON or OFF toggle the [CL] icon
2
.
5. Be sure the Channels and Zones are the same for
meter and the radio receivers in use.
Measuring Screen
(Radio Trigger mode)
Setting
value
Power Control Screen
(ControlTL
®
+
Standard 1~16 Channels)
2
Power Control Screen
(ControlTL
®
+
Standard 17~32 Channels)
3
2
4
5
9
7
8
ControlTL
®
channel &
zone display
Standard
channel &
zone display
Percentage
of ash
Measuring value (f-stop)
1
6