Operation Manual
-23-
6. Advanced Functions
1. Memory function
This meter can store up to nine measured values in memory for incident light and reflected light
independently. This feature can be used in the following modes;
Ambient light : shutter speed priority, aperture priority (L-558 only) or EV mode.
Electronic Flash light : cord, cordless or wireless flash radio triggering mode.
1. Press the Measuring button !4 and take a measure-
ment.
2. Press the Memory button u and store the measured
value in memory.
The number of values in memory is displayed on
the LCD. The memorized value is displayed on the
analog scale. By repeating this operation, up to nine
values can be stored in memory.
3. To clear the memory, press the memory clear but-
ton @3 or switch to another measurement mode.
4. Memory Recall
When the Jog wheel t is rotated while both Memory
button u and the Mode set button !0 are held down
together, the measured value stored in the memory
is displayed along with the memory number. When
any previous stored value is recalled with the ex-
ception of the last stored value, the “M” and number
will blink.
NOTE:
• The memory function cannot be used in “Multiple flash cumulative mode.”
• Measured values for ten times and over will be displayed but cannot be stored in memory.
1/10
f stop
Measured f stop value
Memoreized
f stop values
Set shuttter
speed
Number of memorized value