Operation Manual
-25-
2. Turn any secondary light source off. Point the
Lumisphere toward the main light source, from the
position of the subject and take a measurement. Press
the Memory button u and store the value in memory.
3. Press the AVE./ ∆ EV button r and display the “A”mark
on the LCD indicating a standard value.
4. Turn the main lighting off. Now, point the Lumisphere
toward the secondary light source. While the Measuring
button !4 is depressed and held down, the indicated
difference between the main and auxiliary light sources
is displayed in EV values. At the same time, the
standard value and a new measured value are
displayed on the analog scale.
5. Standard value can be cleared by pressing the Memory clear button @3 , or AVE./ ∆ EV button.
Reference:
• To determine exposure after adjusting lights, turn both main and secondary light sources
on, raise the Lumisphere to the mark position, then take a reading along the camera
light axis in incident light.
• This function can also be used for reflected light.
2 : 1
3 : 1
4 : 1
8 : 1
16 : 1
EV difference of ∆ EV value
Contrast ratio
1
1.5
2
3
4
6. Advanced Functions
Memorized
f stop value
Set shutter speed
Difference
in EV
f stop value
being measured
Now on reading
AVE./∆EV
A
AVE./∆EV
A