Technical data

-53-
H
S
I
L
G
N
E
2) The EV scale displays Clipping points(+/-),Dy-
namic range(+/-)and Mid. Tone with a triangle
" "icon.
3) Measured value exceeding Clipping point will
be displayed as a slow blinking " "
icons.Measurements that exceed the Dynamic
range will be displayed as fast blinking " "
icons.
Reference:
In the custom setting mode (see page 44), it is possible to select how to indicate the
clipping points and the dynamic range. Below are the three display choices.
7. Camera Exposure Profiling
Clipping point(-)
Clipping point(+)
Mid.Tone
Exceed Dynamic
range (blinking faster)
Dynamic range(+)
Dynamic range(-)
Mid. Tone (blinking)
Exceed Clipping
point (blinking slowly)
Five point Inside Range Outside Range
1) After taking a measurement by pressing the Measuring button ,pressing either the
Memory button ,MID.TONE button or AVE./ EV button stores the measured
value as zero in the middle of the EV scale representing the MID.TONE value. Pressing
MID.TONE button will display a blinking “ ” on the scale. Pressing AVE./ EV button
will display a blinking “ ” on the scale.
If the MID.TONE button is not pressed,the measured value will be set automatically in
the middle of the EV scale.(See the section “3-2-3”)
Reference:
In custom setting (see page 44), it is possible to select which value (last measurement,
first memorized value or last memorized value) will become the middle of the EV scale if
the MID.TONE button is not pressed.