Brochure
ESG
8.98.9
8.98.9
8.9
Technical data HT D6005L HT D6005H
Zero switching Yes Yes
Instantaneous switching-on – –
Control circuit DC DC
Load circuit AC AC
Load circuit
Voltage range 24 ... 600 VAC 24 ... 600 VAC
Operating frequency range 10 ... 800 Hz 10 ... 800 Hz
Transient overvoltage 1200 V 1200 V
Load current range 5 mA ... 5 A (25 A)* 5 mA ... 5 A (25 A)*
Max. surge current (10 ms) 300 A 300 A
Max. off-state leakage current (rated voltage) 1 mA 1 mA
Min. off-state du/dt 500 V/μs 500 V/μs
Max. on-state voltage drop 1,6 V 1,6 V
Max. turn-on time 10 ms 10 ms
Max. turn-off time 10 ms 10 ms
Max. I
2
t for fusing (< 10 ms) 450 A
2
s 450 A
2
s
Control circuit
Control voltage range 4 ... 14 VDC 8 ... 32 VDC
Must release voltage 1 VDC 1 VDC
Nominal input impedance 440
Ω
1640
Ω
Typical input current at nominal voltage 25 mA 13,5 mA
Generalities
Insulation input/output 4000 Vrms 4000 Vrms
Ambient operating temperature range -40 ... +80 °C -40 ... +80 °C
Ambient storage temperature range -40 ... +120 °C -40 ... +120 °C
Weight (typical) 15 g 15 g
Approvals UL UL
Article number 42310082 42310083
(Order data see chapter 1)
Printed circuit board mount
Solid-state relay HT
* Up to 25 A can be switched with corresponding cooling. See thermal diagram