Datasheet

ESG 2.15
Dimensions
51
38
80
4713 20
MFT ST22S
MFT ST22S
20
30
40
50
0,2 0,5 1 2 5 10 200,1
100
200
300
Switching current [A]
Switching voltage [V=]
1 pole 12/16A
ohmic load
2 poles 8 A
ohmic load
2 contacts
in series
1 contact
I3 - Pulse detection
When the supply voltage U (K1 closed) is applied, the set
interval t1 begins (green LED U/t flashes slowly) and the
output relay R switches into on-position (yellow LED illumi-
nated). After the interval t1 has expired, the set interval t2
begins (green LED U/t flashes fast). For the output relay to
remain in on-position, the control contact K2 must be closed
and reopened within the set interval t2. If this does not
occur, the output relay R switches into off-position (yellow
LED not illuminated) and all further pulses at the control
contact K2 are ignored.To restart the function, the supply
voltage must be interrupted and reapplied.
Multifunctional clock-pulse generator relay
MFT ST22S
Function descriptions
Load limit curveConnection