Stand-by 0,9 A max @ 48 Vdc
Transmit 7,0 A max @ 48 Vdc
NOTE: current drain values are for fully equipped devices.
Environmental condition:
Operating temperature -30 - +60 °C (-22 - +140 °F)
This is the temperature measured in close proximity to the
device. If the device is mounted in a cabinet, the temperature
within the cabinet is measured.
Humidity should not exceed 90% relative humidity @ 50°C (122°F) non
condensating
Air Quality For equipment operating in an environmentally controlled
environment with repeater(s) rack mounted, the airborne
particle level must not exceed 25 μg/m³.
For equipment operating in an area which is not
environmentally controlled (repeater(s) cabinet mounted), air
borne particle level must not exceed 90 μg/m³.
Equipment Ventilation the repeater is equipped with two cooling fans that are used to
provide forced convection cooling. Customer-supplied
cabinets must be equipped with ventilation slots or openings
in the front (for air entry) and back or side panels (for air to
exit). If several repeaters are installed in a single cabinet, be
sure ventilation openings surround each repeater to allow for
adequate cooling. A minimum of ½ RU (4,4 cm 0,8 inches)
must be left among devices installed in the same cabinet.