User's Manual

Selex ES S.p.A.
Information contained in this document may not be used, applied or reproduced for any purpose unless agreed
by Selex ES S.p.A. in writing
56
LED
Color
Label
Description
1
Green
RX1 busy
RF signal present at the receiver 1
Red
RX1 fail
Receiver 1 PLL unlock
Red blink
RX1 fail
RX1 Equalizer failure
2
Green
RX2 busy
RF signal present at the receiver 2
Red
RX2 fail
Receiver 2 PLL unlock
Red blink
RX2 fail
RX2 Equalizer failure
3
Green
Status 1
RF signal with analog modulation present at the receiver 1
Red
RX1 inhibit
Receiver 1 is in inhibited state
4
Green
Status 2
RF signal with analog modulation present at the receiver 2
Red
RX2 inhibit
Receiver 2 is in inhibited state
5
Green
Status 3
Reserved
Red
Data bus fail
The multichannel data bus is out of frame sync
6
Green
Status 4
Reserved
Red
Logic fail
One of the these error is present:
- DSP/uP communication failure
- logic PLL unlock
Red blink
Logic fail
One of the these error is present:
- boot failure
- EEPROM failure
7
Green
Control bus busy
Activity on the control bus
Red
Control bus fail
control bus among the modules is in failure
Red blink
Control bus fail
Bad message received
8
Green
Upload
Firmware upload in progress
Red
Upload fail
Firmware upload failed