User's Manual

Table Of Contents
Model 1150A DVOR
Rev. - November, 2008
This document contains proprietary information and such information may not be disclosed
to others for any purposes without written permission from SELEX Sistemi Integrati Inc.
3-35
3.6.8
Monitor Screens
3.6.8.1 All Monitor Screens
The following screens provide status, data, and controls applicable to both monitors.
3.6.8.1.1
Monitors Data Screens
3.6.8.1.1.1 Integral Monitor Data Screen
The Integral Monitor screen is shown in Figure 3-31. This screen displays the current integral monitor parameters
for Monitor 1 and Monitor 2. A green background for a parameter indicates that the parameter falls within the Pre-
alarm and Alarm limits. A yellow background indicates that the parameter falls outside of the pre-alarm limits but is
still within the integrity alarm limits. A red background indicates that the parameter falls outside of the alarm limits.
Figure 3-31 Integral Monitor 1 & 2 Data