Table 3-6 Equipment Control Panel Functions
SYSTEM (Refer to Figure 3-63)
Local Control, Switch and
Indicator
Pressing the switch toggles Local Control Mode. The indicator illuminates
when Local Control Mode is enabled. While in Local Control Mode, the
BYPASS, MAIN SELECT, ANTENNA, LOAD and OFF switches are
enabled. When in the remote mode these switches are disabled.
Configuration changes via the PMDT are enabled only while in Local
Control Mode. RCSU control of the VOR is disabled while in the Local
Control Mode.
Alarm Silence Switch
Pressing this switch turns off the alarm tone until a new alarm condition is
detected.
Lamp Test Switch Pressing this switch causes all indicators on the panel to illuminate.
Reset Switch
Pressing this switch resets the system to the power on condition. The LCU,
RMS and all Monitors are reset.
Maintenance Alert Indicator Illuminates to indicate the presence of a maintenance alert condition.
Remote Control Fault Indicator
Illuminates to indicate a failure condition in the communications link to the
RCSU.
Battery Fault Indicator
Illuminates to indicate the presence of a short, open or Battery switch in the
open position.
On Battery Indicator Illuminates to indicate that the VOR is operating on battery power.
Interlocked Off Indicator
Illuminates to indicate the VOR has been turned OFF by the
communications link to the RCSU. Attempts to turn ON the VOR will be
ignored.
LCU Power Ok Indicates that the power supplies are operating normally
Volume
This is a potentiometer control to adjust the level of the aural alarm
indicator.
Table 3-7 Equipment Control Panel Functions
MONITOR (Refer to Figure 3-63)
Integral Normal 1 Indicator Illuminates to indicate the normal condition of monitor 1 integral channel.
Integral Alarm 1 Indicator
Illuminates to indicate the alarm condition of monitor 1 integral channel
after the programmed timeout has expired
Integral Normal 2 Indicator
Illuminates to indicate the normal condition of monitor 2 integral channel.
Integral Alarm 2 Indicator
Illuminates to indicate the alarm condition of monitor 2 integral channel
after the programmed timeout has expired
Integral Bypass Switch and
Indicator
When in Local Mode pressing the switch toggles the bypass condition of
both integral monitors. The indicator illuminates when bypass is active.
Standby Normal 1 Indicator Not Used (OFF)
Standby Alarm 1 Indicator Not Used (OFF)
Standby Normal 2 Indicator Not Used (OFF)
Standby Alarm 2 Indicator Not Used (OFF)
Standby Bypass Switch and
Indicator
Not Used (OFF)