User's Manual

Table Of Contents
Model 1150A DVOR
Rev. - November, 2008
This document contains proprietary information and such information may not be disclosed
to others for any purposes without written permission from SELEX Sistemi Integrati Inc.
9-11
Figure 9-7 Sideband RF Feed Cable to Commutator Connections (Viewed from the rear of the Transmitter
Cabinet)
9.6
INSPECTION
9.6.1 Visual Inspection
The visual inspection is made prior to operating or energizing the equipment.
a. Visually inspect wire, RF coaxial cables and connectors for corrosion, loose connectors and improperly
assembled connectors.
b. Insure all terminal boards are free of foreign objects such as pieces of wire or other objects that could cause
electrical shorts within the equipment. Remove foreign objects as necessary.
c. Inspect the battery backup units to ensure that all terminals and connectors are tight and that there are no
metal shavings or other objects that could cause damage to the equipment.