Data Sheet

Last update: 16 June, 2017
Page: 4 of 5
www.self-ecg.com
Electrical curves:
Electrical curves:
note
For constant current power supply,"LOAD" means the percentage of the maximum rated output voltage.
For constant voltage power supply,"LOAD" means the percentage of the maximum rated output current.
0.90
0.92
0.94
0.96
0.98
1.00
60%
70%
80%
90%
PF
LOAD
PF vs LOAD(230Vac)
600mA
700mA
800mA
900mA
80
85
90
95
60%
70%
80%
90%
100%
EFFICIENCY(%)
LOAD
EFFICIENCY vs LOAD(230Vac)
600mA
700mA
800mA
900mA