User's Manual

51 ProBee-ZE20S Series User Guide Rev.0.1
7.2.11 +++
Description Interrupt data mode. “+++” must be entered within 500ms.
Execute +++
Response OK<CR>
7.3 Node Specific Information
7.3.1 AT+LONGADDR or AT+LA
Description
Get the 64-bit IEEE address. (EUI address, long address) The IEEE address is a
unique device address assigned during manufacturing. This address is unique to each
physical device.
Execute AT+LONGADDR?<CR>
Response
<IEEE address><CR>
OK<CR>
7.3.2 AT+SHORTADDR or AT+SA
Description
Get the 16-bit Node ID. (network address, short address) The node ID of “0000” is
reserved for the coordinator. All other devices receive a randomly generated address
from the router or coordinator device that allows the join. This value can change if an
address conflict is detected where two devices are found to have the same address or
a device leaves the network and later joins.
Execute AT+SHORTADDR?<CR>
Response
<node ID><CR>
OK<CR>
7.3.3 AT+ADDRDISCOVERY or AT+AD
Description Get the corresponding address of a node whose long or short address is known.
Execute AT+ADDRDISCOVERY=<IEEE><CR> AT+ADDRDISCOVERY=<nodeID><CR>
Response
<node ID><CR>
OK<CR>
<IEEE address><CR>
OK<CR>
7.3.4 AT+OPCH or AT+OC
Description
Get the operating channel number used for transmitting and receiving between RF
modules. Uses 802.15.4 channel numbers. A value of “0” means the device has not
joined a PAN and is not operating on any channel.
Execute AT+OPCH?<CR>
Response
<value><CR>
OK<CR>