User's Manual

69 ProBee-ZE20S Series User Guide Rev.0.1
Response
<value><CR>
OK<CR>
OK<CR>
Default 100
Range 0 - 10000
9.2.2 S22
Description
Get/Set the timeout to permit joining. It determines the time in seconds that the device
will allow other devices to join to it when it starts network but an end-device cannot
perform it. If set to 255, the device will always permit joining.
Execute ATS22?<CR> ATS22=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR>
Default 60
Range 0 - 255
9.2.3 S23
Description
Get/Set the power boost mode of the module. If enabled, boost mode improves
sensitivity by 1dB and increases output power by 2dB, improving the link margin and
range.
Execute ATS23?<CR> ATS23=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR>
Default 0
Range 0 – 1
9.3 Data Transmissions
9.3.1 S31
Description
Get/Set the application-ACK mode. If it is enabled, a node retransmits data packet
when it is failed to send. A node sends next packet after receiving ACK from receiver
node. This value must be set the same on the source and destination node for data
transmission.
Execute ATS31?<CR> ATS31=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR>
Default 1
Range 0 - 1
9.3.2 S32
Description Get/Set the transmission retries. If application-ACK is enabled, a sender tries to