User's Manual

26
Parani Multi Wizard supports the Wizard mode and the Manual mode. The Wizard mode provide the
user step-by-step instructions for multiple mode configurations. To run the Wizard mode, select
“Multiple connection mode setting” and “1:N setting”, press “Start” button and follow the instructions.
Figure 3-20 Manual Setting Window
In the Manual mode, all settings for the multiple connection mode can be configured in one window. If
a Use field is unchecked or a slave address is entered as 000000000000, it is excluded from the Slave
settings.
The Auto Fill button will load the existing multiple connection mode settings from the Parani-
SD/ESD/BCD connected, which can be useful when only some parts of the settings are changed.
If the AT Command Response Disable check box is checked on, the AT command responses such as
OK, ERROR, CONNECT, DISCONNECT are suppressed.
3.10. ParaniUpdater
IW05 supports firmware updates. You can download new firmware images for the IW05 at
http://www.senaindustrial.com. With the ParaniUpdater, you can update the firmware of IW05 by
selecting the firmware image file and pushing Start button.
* Note: DO NOT power off IW05 while the firmware update is progressing, this may damage the IW05.