User's Manual

52
Response
OK
Purpose
Change device name
Parameters
$string= New device name (Default=BCDx10_v2.0.6-445566)
Description
IW05 can have a user friendly name for easy identification. The name allows up to 30
alpha-numeric characters.
Example
AT+BTNAME=My-Parani-BCD
B.3.31. AT+BTLPM,n
Response
OK
Purpose
Set low power mode
Parameters
n=0: Inactivate (Default)
n=1: Activate
Description
During no data transmission, IW05 can be in low power mode to save the power.
Low Power Timeout is set to S-register S52.
So if low power mode is activated and if there is no data transfer during a period specified
in S52, IW05 will be entered low power mode.
Please note that it takes a few seconds to make the IW05 out of low power mode.
B.3.32. AT+PASS=$string
Response
Remote Configuration Enabled
Purpose
Input password in remote configuration mode.
Parameters
$string= Password (Default=0000)
Description
Input password for authentication in remote configuration mode.
Example
AT+PASS=1234
B.3.33. AT+CHPASS=$string
Response
OK
Purpose
Change password used in remote configuration mode.
Parameters
$string= New password
Description
Change password used in remote configuration mode. Password length is up to 8.
Example
AT+CHPASS=12345678
B.3.34. AT&V
Response
S0:m0;S1:m1; Sn:mn
OK
Purpose
Display all the S-registers
Description
All parameters are stored at S-register in flash memory. These values are sustained until
hardware reset.
B.3.35. ATSnn?