User's Manual

B.23. S48: Low Power Max Interval (default 5000)
This is the max interval value to use low power mode, which is set to 5000 initially. (5000 x 625μsec =
3125msec)
B.24. S49: Low Power Min Interval (default 4500)
This is the min interval value to use low power mode, which is set to 4500 initially. (4500 x 625μsec =
2812msec)
A small interval increases power consumption, a large interval increases latency.
B.25. S52: Low Power Timeout (default 5)
This is the low power timeout value, which is set to 5 initially. (5sec)
During no data transmission in the timeout, Parani-SD will be in low power mode to save the power.
Therefore, it takes a few seconds to wake the Parani-SD out of low power mode.
B.26. S54: BD Address of Last Connected Device
This saves the Task2 BD address of the Bluetooth device connected most recently in a multiple
connection mode.
B.27. S55: BD Address of Last Connected Device
This saves the Task3 BD address of the Bluetooth device connected most recently in a multiple
connection mode.
B.28. S56: BD Address of Last Connected Device
This saves the Task4 BD address of the Bluetooth device connected most recently in a multiple
connection mode.
B.29. S57: Slave Disconnect Timeout (default 3)
This S57 register value defines the time period in seconds that a master unit waits in case a slave unit
does not receive the data sent from the master. For this time period, the master unit will not send data
to all slave units if any slave unit does not receive the data. If the slave unit does not receive the data
after this time period elapses, the master unit will disconnect the connection with the problematic slave
unit. The value should be greater than 0 and smaller than the Supervision Timeout(S37).
B.30. S58: Current Slave in Communication (default 0)
This value shows the current slave number in communication. The value is automatically stored when
the slave is selected for communication. This value can also be set by user so the master unit
connects to a specific slave to connect first in case the master unit reboots. The value range is 0~4. 0
means the maser unit never connected to a slave. The master will connect to a slave whatever
responses first.
B.31. S59: Reconnect Time Interval (default 5)
This value defines reconnect time interval in case a slave is disconnected in multiple connection mode.
The actual reconnect time interval will be the value multiplied by two in seconds. For example, if the
value is set to 5, the reconnect time interval will be 10 seconds. The value should be greater than or
equal to 5. The master unit will only try to reconnect when its mode is set to Mode1.